Posted By Valentine Jun 07, 2022 07:09:00 AM
Found In Egroup: Automation Control
\ view thread
I reloaded the firmware version 12.00, unfortunately there is no change - the screen saver reverts to 10 minutes timeout each time it is changed and the power is cycled. ------------------------------ Valentine ------------------------------
Posted By Valentine May 27, 2022 02:44:00 AM
Found In Egroup: Automation Control
\ view thread
Hi Fuzzy, sorry about the delay we are in the middle of factory testing. I will try the re-load when I can and report back. Thanks for the suggestion. ------------------------------ Valentine ------------------------------
Posted By Valentine May 05, 2022 10:24:00 AM
Found In Egroup: Automation Control
\ view thread
Hi, We have a couple of PV Plus 7 terminals with the part number 2711P-T9W22D9P and we are trying to set the screen saver idle time to 30 minutes using the Terminal Settings>Display>Screen Saver option. What we find is that when we select the idle time to 30 minutes and cycle power to the terminal ...
Posted By Valentine Feb 01, 2022 11:57:00 AM
Found In Egroup: Automation Control
\ view thread
Hi fuzzy, I installed the patch rollup and created a new display with a new alarm list object. I left all the colours as per the default and changed only the display characteristics of the alarm conditions. Unfortunately it performed the same with the high priority alarms blinking red/grey. Thanks ...
Posted By Valentine Jan 27, 2022 10:51:00 AM
Found In Egroup: Automation Control
\ view thread
Hi fuzzy, many thanks for trying these things out. The Alarm List object appears in every display as we have a 3-line 'alarm banner' at the top of every screen. The snippet in the post above was taken from a 20-line alarm list which appears on an Alarm History screen. Each Alarm List object exhibits ...
Posted By Valentine Jan 27, 2022 07:18:00 AM
Found In Egroup: Automation Control
\ view thread
Hi fuzzy, the alarms are set exactly as you describe with the same settings for active and unacknowledged alarms. The behaviour is the same on the development PC and the PV. The snippet below is taken from the development PC. The image is taken mid-blink, those in black are low priority alarms ...
Posted By Valentine Jan 27, 2022 05:17:00 AM
Found In Egroup: Automation Control
\ view thread
Hi all, we've configured a PV Plus 7 Performance terminal using FT View Studio 12 to show high priority alarms with a background colour set to red and foreground to black, and lower priority alarms with a background colour set to yellow and foreground to black. The alarm list object is set to blink ...
Posted By Valentine Oct 13, 2021 06:50:00 AM
Found In Egroup: Automation Control
\ view thread
Is there Is any protection on the embedded outputs on the CompactLogix 1769-L24ER-QBFC1B PLC? We have accidentally shorted an output to ground causing the output to stop working and can find no information about replacement of fuses or resetting. All other embedded I/O work fine so the fault is ...