Posted By Ian Stones Nov 11, 2022 03:25:00 AM
Found In Egroup: Automation Control
\ view thread
As promised, here it is in V20. Regards, ------------------------------ Ian Stones ------------------------------
Posted By Ian Stones Nov 11, 2022 03:24:47 AM
Found In Library: Automation Control
Posted By Ian Stones Nov 10, 2022 11:08:00 AM
Found In Egroup: Automation Control
\ view thread
I will convert it tomorrow so that you can see what I did. Regards, ------------------------------ Ian Stones ------------------------------
Posted By Ian Stones Nov 10, 2022 04:46:20 AM
Found In Library: Automation Control
Posted By Ian Stones Nov 10, 2022 04:46:00 AM
Found In Egroup: Automation Control
\ view thread
Hi All, Thanks for the responses, I have now solved the issue and it works quite well. I will try to explain how I did it below. I used a bit shift to increment the product along the conveyor as is fairly straight-forward, the sensor at the start of the conveyor provided the '1' bit to increment ...
Posted By Ian Stones Nov 07, 2022 08:31:00 AM
Found In Egroup: Automation Control
\ view thread
Sorry, probably should have said that it's a 1769-L24ER-QB1B processor and a Panelview Plus 7. Regards, ------------------------------ Ian Stones ------------------------------
Posted By Ian Stones Nov 07, 2022 12:41:00 AM
Found In Egroup: Automation Control
\ view thread
Hi All, I have been struggling to think of a way to do this and I am hoping that someone has either done it, or could point me in the right direction. I am trying to animate an HMI application where products are travelling along a conveyor, that bit is simple enough, but at the end of the conveyor ...
Posted By Ian Stones Nov 03, 2022 10:51:00 AM
Found In Egroup: Automation Control
\ view thread
Yes it does, as long as you Cut and not Copy, if they are still in the Controller Tags then the reference won't change. ------------------------------ Ian Stones ------------------------------
Posted By Ian Stones Nov 03, 2022 10:36:00 AM
Found In Egroup: Automation Control
\ view thread
Highlight them in Controller Tags, Cut, and then paste into your Program Tags. You can do it the other way round too. ------------------------------ Ian Stones ------------------------------
Posted By Ian Stones Nov 02, 2022 12:27:00 AM
Found In Egroup: Automation Control
\ view thread
Wescott, Yes that's what I was meaning, as mentioned above too Regards, Ian ------------------------------ Ian Stones ------------------------------
Posted By Ian Stones Nov 01, 2022 12:17:00 AM
Found In Egroup: Automation Control
\ view thread
Hi Wescott, Have you tried to write your own routine and use it as an AOI? That's what we used to do before AOI's were available. Write a routine using a generic local tag i.r. ParRobot KA and then call the routine using your actual tag, the same as you would use an AOI. Regards, Ian ...
Posted By Ian Stones Jul 11, 2022 08:00:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi Jesse, Thanks for your response, very much appreciated. I have been doing some homework on this, based on your suggestion and it looks like you move the parameter shown below into the System Variable Monitor location and it maps all of the digital inputs into a status word to read from the drive ...
Posted By Ian Stones Jul 03, 2022 06:44:00 PM
Found In Egroup: Automation Control
\ view thread
Hi All, We have a weird anomaly with our PanelView+ 7 Standard 10" running on Version 11 runtime. PLC is a 5069-L320ERS2 on FRN 32.012. It has taken a bit of investigating to find out what is causing the issue, but we feel we have pinpointed the culprit. It does seem strange so I am not sure if ...
Posted By Ian Stones Jul 01, 2022 01:04:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi All, Does anyone know if it is possible to read the digital input status of a Kinetix 5100 servo drive? Regards, Ian ------------------------------ Ian Stones ------------------------------
Posted By Ian Stones Jun 21, 2022 04:09:00 AM
Found In Egroup: Automation Control
\ view thread
Hi Ian, Thanks for your response, this was my thinking also. I didn't know if anyone knew of a way of protecting the security configuration when downloading, but I think your suggestion of uploading the runtime file first is the only way to keep the data. Regards, Ian ------------------------------ ...
Posted By Ian Stones Jun 20, 2022 03:36:00 AM
Found In Egroup: Automation Control
\ view thread
Hi All, We have an application that uses am RFID card reader to add users to a PanelView Plus 7 application and I wondered if there is someone that can confirm whether we would lose these users if a modification was made to the application and then downloaded? Is there any way to download without ...
Posted By Ian Stones Feb 09, 2022 07:37:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Thanks for your response, we have version 2.01.17.0 AOP so I don't think this is the issue. Regards, Ian Stones Process Automation UK Ltd Get Outlook for Android
Posted By Ian Stones Feb 01, 2022 01:10:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi All, I am having some issues with the configuration signature on a few Kinetix 5100 drives. If you cycle the power to the control panel all of the Kinetix 5100 drives go into, what looks like, a STO fault. After some investigation it turns out that this is due to differences in the drive configuration ...
Posted By Ian Stones Feb 01, 2022 12:35:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Have you managed to solve this issue? I have done the registration using an inductive proximity switch and I wouldn't have thought that it would be much different, what is your specific issue? Regards, Ian ------------------------------ Ian Stones ------------------------------