Hi All! I want to enable security in my 1756-L71, but the functions are not active in the Security tab (see attached screenshot). Before, I created a premision set in the FactoryTalk Administrations Console. I use Studio 5000 V31.00.00. Please, give me any advices. ------------------------------ ...
Posted By ValRin Aug 22, 2021 12:41:00 PM
Found In Egroup: Automation Control
\ view thread
Thanks, it was very useful information for me. The EN2T module is connected to a ModbusTCP gateway​, converts Modbus to EtherNet/IP. I think ,in my case, the solution is to use the ModbusTCP server sample code. As I understand, it uses CIP Class 3 connections (correct me if I'm wrong).
Posted By ValRin Aug 21, 2021 11:00:21 AM
Found In Library: Automation Control
Posted By ValRin Aug 21, 2021 11:00:00 AM
Found In Egroup: Automation Control
\ view thread
Hi @fuzzy logic!​​ Thanks for reply! Sorry, I didn't write in my post: i changed IP address only for EN2T module in slot 2, it didn't work. And as you mentioned earlier my EN2T module is not used for I/O or Produced/Consumed connections. In RMCT, on primary chassis, there was error message for EN2T ...
Posted By ValRin Aug 20, 2021 12:22:00 PM
Found In Egroup: Automation Control
\ view thread
​Hi all! I have a redundant controllogix 1756-L71 (Rev 31.052) with an EN2T card in slot 2 for Ethernet / IP, EN2TR in slot 3 for remote I / O. My redundant system uses IP swapping, but I need to use it without IP swapping. To do this, I changed the IP address in the secondary rack (changed from AAA.BBB.CCC.DDD ...
Posted By ValRin Feb 17, 2020 12:08:00 PM
Found In Egroup: Automation Control
\ view thread
The redundant communication channel is a mandatory technical requirement of our plant and applies to all third-party PLCs, it is was implemented on PLCs of another manufactures. We can to change our system network located below switch#3 and 4, but not the top, because another PLCs communicate ...
Posted By ValRin Feb 17, 2020 04:15:00 AM
Found In Egroup: Automation Control
\ view thread
Thanks for reply! If I understand correctly, you suggest that, I have to connect the EN2TR cards, I/O AENTR and DLR switches (instead switch#1 and 2) in one ring. But in this case, problem still remains, because FTE connections (left and right side in my topology) will be interconnected in this ...
Posted By ValRin Feb 15, 2020 01:11:00 PM
Found In Library: Automation Control
Posted By ValRin Feb 15, 2020 01:11:00 PM
Found In Egroup: Automation Control
\ view thread
Yes, you are right, It is MOXA-5105. I described the topology as below. The problem is in Link#1. Our DCS system uses FTE and it doesn't work in the ring ##HL38
Posted By ValRin Feb 15, 2020 01:03:00 PM
Found In Egroup: Automation Control
\ view thread
Yes you are right. This is MOXA-5105. I described the topology as below. The problem is in Link#1. Our DCS system uses FTE and it doesn't work in the ring ##HL38
Posted By ValRin Feb 15, 2020 11:11:00 AM
Found In Egroup: Automation Control
\ view thread
Summary: Redundancy system in FTE network We need integrate CLX redundancy rack in FTE network for ModbusTCP data exchange with DCS. Each rack has EN2T card and connects to MOXA 5150 gateways, which converts Ethernet/IP to ModbusTCP. The problem is follow: for normal operation, a connection between ...