Posted By Jhon Mar 07, 2024 04:33:33 PM
Found In Egroup: Advanced Software
\ view thread
Hello. I have just read the article completely and it highlights that if the server and opc client are hosted on the same PC then DCOM security does not affect at all whatever the DCOM configuration. Is this the case with the HMI FTV SE v.11 server (local) working with a third-party driver through ...
Posted By Jhon Mar 06, 2024 04:45:20 PM
Found In Egroup: Advanced Software
\ view thread
Hello. Always grateful for your information. But it does not work My tags after configuring DCOM still do not have good quality using matrikon explorer I have followed all DCOM configuration recommendations including disabled windows firewall and lower level UAC accounts. But I don't get anything. ...
Posted By Jhon Feb 26, 2024 05:55:00 PM
Found In Egroup: Advanced Software
\ view thread
Hello. I would like to simulate on my PC a project of a third-party controller with opc DA also of third parties and factorytalk view is v.11 in undistributed local mode. The live factoytalk client has access to the tags because it runs as a user account.The third-party opc server also runs as ...
Posted By Jhon Feb 07, 2024 05:30:09 PM
Found In Egroup: Advanced Software
\ view thread
I feel very sorry, startup and activation permissions>custom>local service when you reset pc this returns to default, there is no option to customize it After reset pc goes back to default There is no way to start and activate permissions, everything returns to default In access permissions and configuration ...
Posted By Jhon Feb 07, 2024 12:04:44 PM
Found In Egroup: Advanced Software
\ view thread
Thank you,my tags in client is good Refreshing some have access and many others do not How to change this to Local Service? On this server everything is perfect I need to start OPC server as Local Service, how to do it? I think that despite everything there is another problem, my labels are enabled ...
Posted By Jhon Feb 05, 2024 04:52:33 PM
Found In Egroup: Advanced Software
\ view thread
Philip, My application runs in local mode, factorytalk client and HMI are on the same PC. Is it necessary to configure DCOM if everything runs on the same PC? Even if everything is running on the same PC, do you have to configure DCOM?
Posted By Jhon Feb 04, 2024 11:23:00 AM
Found In Egroup: Advanced Software
\ view thread
Hello, I happen to be running FTV SE v.11 in non-distributed localhost mode on Windows 10. I am using a third-party OPC (OFS OPC Schneider v.3.63) to connect in simulation mode with the PLC also from Schneider, everything runs on the same PC. As you can see in the image, the FTV SE client and OFS (third-party ...