Posted By Luke Josten Jan 02, 2024 02:32:00 PM
Found In Egroup: Automation Control
\ view thread
I exported both the tag CSV that I edited which did not work, and the Tag CSV that worked after redoing every single tag. They look identical in Notepad++. Here it is attached. What doesn't make sense is I could go through every tag in the database and find it in the tag browser, yet the syntax would ...
Posted By Luke Josten Jan 02, 2024 10:00:00 AM
Found In Egroup: Automation Control
\ view thread
The comms were set up correctly so that wouldn't have been the issue. Like I said, after downloading I was even checking the path within the terminal config settings and it was pointing to the correct path. "The BT instructions in the PLC point generally to N-files... Remove the BT instructions and ...
Posted By Luke Josten Dec 28, 2023 07:36:00 AM
Found In Egroup: Automation Control
\ view thread
Philip, I originally went down to the terminal and plugged my laptop into that device network. I then opened comms setup and copied my tree over to runtime and selected the PLC on both. Everything looked good and it appeared FTLinx Network Browser was able to see everything on the device net from that ...
Posted By Luke Josten Dec 27, 2023 04:15:00 PM
Found In Egroup: Automation Control
\ view thread
I was given the glorious task of converting a Panelview Plus 1250 v5.10 from Data Highway to Ethernet. The previous communication was over bit transfer and utilized the tag database within the .mer. I went thru the PLC and created actual tags to replace the bit transfer tags then updated every tag in ...
Posted By Luke Josten Jan 24, 2023 10:01:00 AM
Found In Egroup: Automation Control
\ view thread
Instead of test display I did the Test Application like you asked. It was throwing up constant errors with tags "[FactoryTalk]: The Item is no longer available". I went to one of the many tags listed from HMI Tags. The tag it referenced in the PLC looked correct. To double check syntax I went into ...
Posted By Luke Josten Jan 24, 2023 07:50:00 AM
Found In Egroup: Automation Control
\ view thread
My employer is having me upgrade an old Data Highway system to Ethernet. Everything has gone without a hitch until I attempted to convert the Panelviews. All the panelviews in this system are v5.10 and utilize HMI tags which reference bit transfer tags in the PLC. A coworker said I should be able ...
Posted By Luke Josten Jun 23, 2022 03:41:00 PM
Found In Egroup: Automation Control
\ view thread
I copied an image of a pump from symbol factory library to the image browser to be used as a multistate indicator. When in symbol factory it makes me choose a color or leave it as the default. The issue I'm having is the multistate indicator pump image stays the same color that it was copied in as, regardless ...