Posted By Garcia Avila Sep 27, 2024 03:16:00 PM
Found In Egroup: Advanced Software
\ view thread
Hello everyone I have a project with 12 machines with the same plc code. It's very slow for me to download by one by one, I try to understand how the Logix designer is used with the manual, but it's not clear, Someone help me with video or more details Anyway
Posted By Garcia Avila Sep 27, 2024 11:13:00 AM
Found In Egroup: Automation Control
\ view thread
Hello Arp i hope helps this: https://literature.rockwellautomation.com/idc/groups/literature/documents/at/safety-at085_-en-p.pdf EDIT: fixed link URL -FL
Posted By Garcia Avila Sep 20, 2024 09:45:00 AM
Found In Egroup: Automation Control
\ view thread
Thanks for your support. okey understood, but now i used the version 1756-L73 with version V33. request of customer. other option ?
Posted By Garcia Avila Sep 19, 2024 05:33:00 PM
Found In Egroup: Automation Control
\ view thread
Hi everyone. I have been working on an application for a German competitor and I have managed to communicate a JSON file and API to obtain data etc. Any suggestions for a non-rockwell API for 3rd party compact and controllogix or on linux. Thanks for your comments. EDIT: moved to Automation ...
Posted By Garcia Avila Sep 13, 2024 02:40:11 PM
Found In Egroup: Automation Control
\ view thread
Thanks Norman and Batman i attached the logic This first scan cycle commands the setpoint position, and later in the second subroutine is: P210_Rotate_Deglazing_Brush_To_Advanced sends the start command, I wonder if I do create a new (periodic) task for the subroutine that sends the data to the servo ...
Posted By Garcia Avila Sep 12, 2024 04:28:00 PM
Found In Egroup: Automation Control
\ view thread
Hello community I migrated 1769-L36ERMS to 5069-L34ERMS2 but I have a small problem with Siemens servo drive. The problem is: when I command start and send setpoint position, PLC scan is faster than before, so Sinamics S120 can't see update data. Servo drive never moves. I put a small delay of 100ms. ...
Posted By Garcia Avila Sep 12, 2024 09:04:37 AM
Found In Egroup: Automation Control
\ view thread
Excellent contribution, but as Shane mentions. When you connect to a PLC it is to make an improvement to the system or optimize it. (If the PLC was well programmed) I believe that there are tools in PLC programming to help with the HMI. You can use a state machine where each step tells the user a description ...
Posted By Garcia Avila Aug 27, 2024 09:17:49 AM
Found In Egroup: Networks
\ view thread
Hi Early my suggestion is to use software of rockwell: FactoryTalk Network Manager I think the license are chip so good option to mapping your network with DLR.
Posted By Garcia Avila Aug 23, 2024 01:02:03 PM
Found In Egroup: Automation Control
\ view thread
Thanks a lot for your support. Regards
Posted By Garcia Avila Aug 23, 2024 10:46:40 AM
Found In Egroup: Automation Control
\ view thread
Thanks Shane, do you know any application or something that will be thin or something VS to be able to run it without consuming so many PC resources?
Posted By Garcia Avila Aug 23, 2024 10:43:03 AM
Found In Egroup: Automation Control
\ view thread
Thanks Ron, Could you share example of technical note? i appressed your support and help. Regards.
Posted By Garcia Avila Aug 22, 2024 04:34:00 PM
Found In Egroup: Automation Control
\ view thread
Hello everyone is my first time use the forum. It is possible for a controllogix to send data to a notepad via a message? Now i have panelPC with windows 10. so, i wonder if can configure message with socket or something like that, sends data plc to notepad of windows.