Posted By Phong Nguyen Nov 20, 2023 07:49:28 AM
Found In Egroup: Networks
\ view thread
Thank you for your help. ------------------------------ Phong Nguyen ------------------------------
Posted By Phong Nguyen Nov 19, 2023 08:50:00 PM
Found In Egroup: Networks
\ view thread
Thank you. I find the reason. For FC2 the internal address must interpreted as a bit level address. If I set an internal address for FC2 as 1000 it's wrong, should be set at 16000. ------------------------------ Phong Nguyen ------------------------------
Posted By Phong Nguyen Nov 13, 2023 09:27:26 PM
Found In Library: Networks
Posted By Phong Nguyen Nov 13, 2023 09:27:00 PM
Found In Egroup: Networks
\ view thread
Yah, I can see the Read Input (1x) in ProSoft Database ( 0 - 99). It should be at ProSoft Database from 1065 - 1075 correct ? Please see the picture. Pic 1 & 2: Read holding (4x) Pic 3 to 9: Read Input (1x) ------------------------------ Phong Nguyen ---------------------- ...
Posted By Phong Nguyen Nov 10, 2023 09:30:06 PM
Found In Library: Networks
Posted By Phong Nguyen Nov 10, 2023 09:30:00 PM
Found In Egroup: Networks
\ view thread
I have attached communication trafic for diagnostic. Pic 1 & 2: Read Input (1x) Pic 3 & 4: Read holding (4x) ------------------------------ Phong Nguyen ------------------------------
Posted By Phong Nguyen Nov 10, 2023 02:14:00 AM
Found In Egroup: Networks
\ view thread
Hi Ian Shaw, I do not map anything to Internal Register 1000. I have make another test. I create Client Command 3 for Read Holding Register at Internal Address 1000, Reg count 10 I create Client Command 4 for Read Input at Internal Address 1010, Reg count 10 Use Client software ...
Posted By Phong Nguyen Nov 10, 2023 02:13:56 AM
Found In Library: Networks
Posted By Phong Nguyen Nov 08, 2023 09:17:00 AM
Found In Egroup: Networks
\ view thread
Hi, I get trouble when try to read data from MNET card via Modbus TCP. Although I can read Holding Register(4x) , but Input(1x) can not. EDIT: moved to Networks community -FL ------------------------------ Regards, Phong Nguyen ------------------------------
Posted By Phong Nguyen Nov 08, 2023 09:16:34 AM
Found In Library: Networks
Posted By Phong Nguyen Apr 28, 2023 01:24:54 AM
Found In Egroup: Advanced Software
\ view thread
Thank you. ------------------------------ Phong Nguyen ------------------------------
Posted By Phong Nguyen Apr 27, 2023 10:41:00 PM
Found In Egroup: Advanced Software
\ view thread
Good morning everybody. How we can assign HMI tags/constant value for Display Element - Process Library v4.0 ? I mean for example assign value 5 for parameter #102 of P_AIn Graphic Display without make Object tag in PLC. Tks. ------------------------------ Phong Nguyen ---------------------- ...
Posted By Phong Nguyen Dec 13, 2022 09:43:00 PM
Found In Egroup: Automation Control
\ view thread
Hi, Thank you for your advice. I just want setup a virtual environment for testing Modbus TCP with Logix Emulate. ------------------------------ Phong Nguyen ------------------------------
Posted By Phong Nguyen Dec 12, 2022 06:35:00 PM
Found In Egroup: Networks
\ view thread
Hi, Yes, I type a mistake... . L63 go with EN2T module for Modbus communication. We can ping to Chiller when connect laptop to Switch 5700 by Modbus Poll software. We are not sure that the Smart port on Switch 8000 config as Automation Device & Switch For Automation, which can have adverse effects ...
Posted By Phong Nguyen Dec 12, 2022 06:21:00 AM
Found In Egroup: Networks
\ view thread
Hi, I use Logix L63 to connect to Carrier Chiller via Stratix 8000 by Modbus TCP. Logix L63 Stratix 8000 (Automation Device) & (Switch For Automation) Stratix 5700 (None Config) Carrier Chiller Please refer photo for more detail. The problem that I cannot link to device. How I can resolve ...
Posted By Phong Nguyen Dec 12, 2022 06:08:00 AM
Found In Egroup: Automation Control
\ view thread
Thank you ------------------------------ Phong Nguyen ------------------------------
Posted By Phong Nguyen Dec 12, 2022 06:08:00 AM
Found In Egroup: Automation Control
\ view thread
Thank you ------------------------------ Phong Nguyen ------------------------------
Posted By Phong Nguyen Dec 12, 2022 02:53:00 AM
Found In Egroup: Automation Control
\ view thread
Hi, I want to make Logix Emulate communicate with Modbus Slave software. I import Modbus TCP Client AOI to test, but it get error (-8 create Soc failed). Could you help to advise ? Thanks. ------------------------------ Phong Nguyen ------------------------------
Posted By Phong Nguyen Nov 21, 2022 03:23:00 AM
Found In Egroup: Advanced Software
\ view thread
Thank you for your advice. ------------------------------ Phong Nguyen ------------------------------
Posted By Phong Nguyen Nov 18, 2022 01:22:00 AM
Found In Egroup: Advanced Software
\ view thread
I noted. ------------------------------ Phong Nguyen ------------------------------