List of Contributions

Phil Schiavo

Contact Details

Phil Schiavo


My Content

1 to 8 of 8 total
Posted By Phil Schiavo Mar 04, 2024 08:02:16 AM
Found In Library: Automation Control
Posted By Phil Schiavo Mar 04, 2024 08:02:00 AM
Found In Egroup: Automation Control
\ view thread
Hi Maybelle, A copy of the EDS file for the 842D encoder is attached. Parameter 1 controls the counting direction. It has been a long time since I worked with DNet. If I remember correctly you need to do a download of the configuration to the new encoder to install it from RSNetworx for DNet to ...
Posted By Phil Schiavo Nov 29, 2023 06:53:00 AM
Found In Egroup: Automation Control
\ view thread
Hi Tim, Yes, you can use only one of the contacts in the 440J enabling switch if your system is single channel. Most safety devices have multiple channels so that they can be used in safety circuits from Category 1, PL a to Category 4, PL d safety systems. ------------------------------ ...
Posted By Phil Schiavo Nov 21, 2023 07:07:00 AM
Found In Egroup: Automation Control
\ view thread
Hi David, It sounds like you may have a bad sensor or actuator. I suspect it's the actuator that is bad. I suspect the 8X blink you are seeing is that the switch still has eight actuators it can learn. The test I am suggesting will cost you one of the eight learns of the Sensaguard switch. You ...
Posted By Phil Schiavo Nov 06, 2023 01:41:00 PM
Found In Egroup: Automation Control
\ view thread
The attached code works for the 58UHF. You can open the acd file and copy the rungs into your program and modify them as needed. ------------------------------ Phil Schiavo ------------------------------
Posted By Phil Schiavo Nov 06, 2023 12:39:21 PM
Found In Library: Automation Control
Posted By Phil Schiavo Jan 09, 2023 08:20:00 AM
Found In Egroup: Automation Control
\ view thread
Hello Tyson. The 450L-B light curtains have a range of 1.64 feet to 13,1 feet for 14 mm resolution sticks. The range for 30 mm resolution sticks is 2.95 feet to 23 feet. There are two LEDS that look like stacked lines. If those are not lit the OUT LED will not turn Green. See the image below. -- ...
Posted By Phil Schiavo Sep 02, 2022 09:54:00 AM
Found In Egroup: Automation Control
\ view thread
EDIT: corrected link to the user manual as it was shown incorrectly -FL The user manual has diagnostics and troubleshooting steps in Chapter 7. That would be a good place to start. https://literature.rockwellautomation.com/idc/groups/literature/documents/um/440g-um002_-en-p.pdf You can call ...