List of Contributions

CarBronco

Contact Details

CarBronco


My Content

1 to 6 of 6 total
Posted By CarBronco Feb 16, 2026 08:04:39 AM
Found In Egroup: Advanced Software
\ view thread
What worked for a customer was using the full domain name to login: in the example above login with ac-test.local\ (or user@ac-test.local) instead of ac-test\ or just . -------------------------------------------
Posted By CarBronco Feb 16, 2026 02:58:57 AM
Found In Egroup: Advanced Software
\ view thread
@Riemer Fix is underway, as a temporary workaround you can try forcing the query to the Global Catalog on port 3268 unencrypted or 3269, like: ldap:\\ :3268 ldaps:\\ :3269 -------------------------------------------
Posted By CarBronco Feb 16, 2026 02:58:00 AM
Found In Egroup: Advanced Software
\ view thread
@Riemer Fix is underway, as a temporary workaround you can try forcing the query to the Global Catalog on port 3268 unencrypted or 3269, like: ldap:\\ :3268 ldaps:\\ :3269 EDIT: use the full domain name to login: in the example above login with ac-test.local\ (or user@ac-test.local) instead ...
Posted By CarBronco Jul 30, 2025 02:34:00 AM
Found In Egroup: Advanced Software
\ view thread
Hello, as reported in this KB article https://support.rockwellautomation.com/app/answers/answer_view/a_id/1135188, a single Linx Data Server instance can handle up to 300 shortcuts and 100k tags on-scan. you can have up to two instances of a Linx Data Server on a single computer. Several factors (listed ...
Posted By CarBronco Apr 03, 2025 01:44:00 AM
Found In Egroup: Advanced Software
\ view thread
Hi Thakar, if you have TechConnect you can refer to the following technotes: Upgrade FactoryTalk View SE 7.0 or newer to a newer version of FactoryTalk View SE Tool: Converting FactoryTalk View SE HMI Alarms to Alarm and Event Tag-Based Alarms There's no incremental upgrade; new ...
Posted By CarBronco Apr 01, 2025 05:17:00 AM
Found In Egroup: Advanced Software
\ view thread
Hi, FT View SE Server - Client connection is on top of Microsoft IIS (Internet Information Services). TCP port depends on the binding; in general would be TCP:80 if HTTPS is disabled, TCP:443 if HTTPS is enabled. You can verify port binding opening Internet Information Services (IIS) Manager on Windows. ...