Posted By Conneely Sep 18, 2025 07:53:00 AM
Found In Egroup: Automation Control
\ view thread
Yes, I'm aware of it and did try and target the specific port to see if it would load but couldn't get it to work. The issue I have with the tech note is that it references the 'FactoryTalk View ME Station logs' which I interpret as PV system logs not DataStore+ logs. In response to an RA support ticket ...
Posted By Conneely Sep 18, 2025 07:07:00 AM
Found In Egroup: Automation Control
\ view thread
I've encountered 'Major Non-Recoverable Fault' due to an out-of-bounds array which I overlooked before pushing to the PLC. If you can 'Go Online' with the system in fault, navigate to the 'Controller Properties' and select the 'Major Faults' tab. Then within the 'Major Faults' tab under the 'Recent Faults' ...
Posted By Conneely Sep 18, 2025 06:33:00 AM
Found In Egroup: Automation Control
\ view thread
A system that we are working on utilises a PanelView Plus 6 which is being replaced by a Panel View Plus 7 Performance Ser B due to obsolescence. The log files generated by the DataStore+ system are uploaded from the PanelView 6 over FTP using a web UI but we're encountering issues with this on the ...
Posted By Conneely Mar 20, 2025 09:23:00 AM
Found In Egroup: Automation Control
\ view thread
I've been tasked with investigating some condition monitoring devices in order to make comparison and inform a decision of the best solution for our system. One of those devices is a Historian ME (1756-HIST2G) for which I have downloaded and thralled through numerous guides and technical notes but I'm ...
Posted By Conneely Feb 10, 2025 04:53:00 AM
Found In Egroup: Automation Control
\ view thread
Hello @Delete, Thanks for responding to the query, I'm going to experiment with the recommended instructions to see if it works for our purpose. We're very likely to go down the ST AOI route but wanted to put it out there to see if others are encountering a similar issue. Thanks again ...
Posted By Conneely Feb 05, 2025 03:31:00 AM
Found In Egroup: Automation Control
\ view thread
Swap byte (SWPB) instruction – Endianness / Alternative AOI The SWPB instruction doesn't seem to work for our purposes and we are trying to find a solution for this. The SWPB seems to only swap the byte order in a single var and copy it into another var of the same size as long as both vars are ...