List of Contributions

Alhabbashi

Contact Details

Alhabbashi


My Content

1 to 20 of 21 total
Posted By Alhabbashi Feb 14, 2024 03:09:00 AM
Found In Egroup: Legacy
\ view thread
Hello guys Hope all is well I have been checking out to find out Eplan/DWG files for legacy staff such as SLC5 and RIO, I/O .. I only found other products on Eplan Library. Your help will be much appreciated
Posted By Alhabbashi Feb 05, 2024 02:20:39 AM
Found In Egroup: Legacy
\ view thread
Thank you so much and that is really clear cut now. I am in field break now, Will let you know soon I got back to work. I really highly appreciate it
Posted By Alhabbashi Feb 03, 2024 03:05:38 AM
Found In Egroup: Legacy
\ view thread
Thank you so very much for your reply. it is really helpful. So to put that in practice, I need to change my DH485 Network configuration, see the below picture please, I will then use only two AIC Link couplers as the ESD1 and ESD2 will have same node, and both are interconnected same as in the ...
Posted By Alhabbashi Feb 01, 2024 09:06:00 AM
Found In Egroup: Legacy
\ view thread
Thank you so much for your unwavering support. I am not sure if I have explained my question well. The two PLCs are already working but I am designing a SCADA . With respect to the Two Redundant SLCs, let us say ESD1 SLC and ESD2 SLC, when I came to create HMI tags in the Wincc Advanced software. ...
Posted By Alhabbashi Feb 01, 2024 05:35:00 AM
Found In Egroup: Legacy
\ view thread
Hello guys I really appreciate your support. I am integrating a number of a legacy SLCs into a Wincc advanced using the DF1 protocol. I am facing an issue with to redundant SLCs (both have same program) , and both are connected in a DH485 network with different nodes. until here no problem, I was ...
Posted By Alhabbashi Feb 01, 2024 01:35:18 AM
Found In Egroup: Legacy
\ view thread
No, I only tried the DH485 UIC driver and I see all nodes
Posted By Alhabbashi Jan 31, 2024 01:10:22 PM
Found In Egroup: Legacy
\ view thread
Yes of course, and thank you so much for your suggestion highly appreciated.
Posted By Alhabbashi Jan 31, 2024 02:06:00 AM
Found In Egroup: Legacy
\ view thread
Thank you so very much for the confirmation , So I need to use SN instead of BSN I have found that why the BTR/W are greyed out as " Block transfer instructions are supported by SLC 5/03 (OS302, Series C), SLC 5/04 (OS401, Series C) and SLC 5/05 (OS501, Series C) and higher processors only." ...
Posted By Alhabbashi Jan 30, 2024 03:52:57 AM
Found In Egroup: Legacy
\ view thread
Thank you very much for your response. I already managed to play with the addressing of digital siganls, Said that, as I mentioned I still have the Error Leds flashes on the BSN modukle. Can you please confirm this is because I am using one SLC5/3. In other words, can I use the BSN module only with ...
Posted By Alhabbashi Jan 28, 2024 01:36:00 AM
Found In Egroup: Legacy
\ view thread
Hello guys. I wonder if it is possible to insert analogue module in RIO, I have connected a digital signal and have a good understanding of the addressing modes variants i.e 1 slot, two slot, or 1/2 slot. However, my project requires installing two analogue modules in 1746_A7 chassis. The example ...
Posted By Alhabbashi Jan 27, 2024 10:00:00 AM
Found In Egroup: Legacy
\ view thread
Thank you very much for your response, I managed to connect after chaning the C13 cable
Posted By Alhabbashi Jan 27, 2024 09:59:00 AM
Found In Egroup: Legacy
\ view thread
Hello guys I have been trying to add a RIO to an existing system for upgrade purpose, so I have grapped a BSN and ASB and set them up on the workshop. because the mapping and addressing sounds complicating in Manuals, maybe because am coming from Siemens background! - I, therefore, wanted to see them ...
Posted By Alhabbashi Jan 23, 2024 03:09:43 AM
Found In Egroup: Legacy
\ view thread
Thank for your reply. yes as I have previously stated that I was able to connect point to point and assigned unigue address for each. ------------------------------ Alhabbashi ------------------------------
Posted By Alhabbashi Jan 23, 2024 12:44:17 AM
Found In Egroup: Legacy
\ view thread
yes, same cable 1747_C13 is used between the UIC and SLC 1747-C10, which was provided with the coupler, is used between the SLC and Coupler I used the DH485 UIC devices driver. Please note that I was able to connect point to point to SLC using the C13 and UIC adapter and DH485 UIC driver. ...
Posted By Alhabbashi Jan 22, 2024 10:49:02 AM
Found In Library: Legacy
Posted By Alhabbashi Jan 22, 2024 10:49:00 AM
Found In Egroup: Legacy
\ view thread
Hello guys. Thank you very much for your continued support. I am trying to establish a DH485 Network connection between two SLC5/3 controllers. I am using the following. Two DH485 Link couplers 1747-AIC with the provided cable 1747-C11 one 1747_UIC adapter to be connected to my personal computer. ...
Posted By Alhabbashi Sep 20, 2023 09:11:31 AM
Found In Egroup: Legacy
\ view thread
Thank you very much for reply It is, indeed, much clearer now especially with your last point : With the complete system, a connection would finally be created between PLC (or Emulator) --> FactoryTalk Linx --> FactoryTalk Linx Gateway (OPC server) --> OPC Client" Said that, can you confirm ...
Posted By Alhabbashi Sep 20, 2023 09:11:30 AM
Found In Library: Legacy
Posted By Alhabbashi Sep 20, 2023 02:41:00 AM
Found In Egroup: Legacy
\ view thread
EDIT: corrected product name for clarity -FL Thank you for sharing I watched a video. I now know why I need RSLinx FactoryTalk Linx Gateway Thanks a ton for sharing. ------------------------------ Alhabbashi ------------------------------
Posted By Alhabbashi Sep 20, 2023 02:31:52 AM
Found In Egroup: Legacy
\ view thread
Thank you so much for your reply. I highly appreciate it I have solved the issue by using the OPC Matrikon that enables me to connect to ControlLogix as well as a legacy PLC with no issue, it works so smooth and perfect. Referring to your answer. I do not have RSlinx Gateway or FactoryTalk Linx ...