Posted By Ant Jun 01, 2026 08:56:00 AM
Found In Egroup: Automation Control
\ view thread
Any suggestions, returned to site to complete commissioning a system. I have a 9" PV+ with 5380 CPU all comms between CPU and HMI fine however the HMI is un-discoverable via FT Linx and unable to Ping it. I have verified the IP address / Subnet is correct. Left site two weeks ago it was accessible and ...
Posted By Ant May 13, 2025 01:25:00 AM
Found In Egroup: Automation Control
\ view thread
Hi Keith I swapped out the SD Card and all working fine thanks. Regards Ant
Posted By Ant May 08, 2025 02:55:00 AM
Found In Egroup: Automation Control
\ view thread
I am using View Designer Ver 9 with a number of PV5510 HMI's and PLC's at Ver 36.11. I am unable to get the data logging working,I have tried 2 separate HMI's. Unfortunately I only have 1 card although I will bring another one to site next week to rule out card issue. The card is a New SDHC Card ...
Posted By Ant Feb 21, 2025 01:46:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Anything from 20m to 40m yes they are twisted pairs, I have run a separate encoder and motor cable outside of the conduit exhibiting the same fault. Irrespective of how many drives I run the same axis's fault. (I also have 40 other 525 drives running other sections). The fault appears to follow ...
Posted By Ant Feb 19, 2025 09:30:00 AM
Found In Egroup: Automation Control
\ view thread
Thanks I found it:- https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1125503/loc/en_US
Posted By Ant Feb 19, 2025 03:18:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi Batman sorry I should have been a bit clearer, the trip happens after having run for a period of time, not had any instances on startup. Unfortunately the encoders are 5V supply and can only feed them with 5V. To eliminate any possible drive issue I have also powered the Encoder directly from a desktop ...
Posted By Ant Feb 19, 2025 12:26:00 AM
Found In Egroup: Automation Control
\ view thread
Is is possible to synchronise the PV5000 HMI with a Logix CPU Date and Time (as was possible with a PV+). I know you can use the Predefined DateAndTime popup to set each HMI local date / time. But would rather all 5 x HMI's simply sync with the CPU. Thanks Ant #PV5000 #ControlLogix #PVP7
Posted By Ant Feb 18, 2025 08:58:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
I am commissioning a system comprising of 9 x 5700 Double Motor Modules, running AC Induction Motors with Sin/Cos Encoders and Universal Feedback Module. Am experiencing persistent trips on a number of Axis, S43 - Feedback Signal Loss. I have checked the Volts to Encoders are 5.1V @ 40mA (ish), ...