List of Contributions

GLaDOS

Contact Details

GLaDOS


My Content

1 to 20 of 50+ total
Posted By GLaDOS Mar 05, 2026 08:42:12 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
HogueGregPLC, Yes, you can pull the value with a MSG instruction. There is an example technote here: PowerFlex 525: Explicit message setup to read and write to drive parameters ID: QA54963 | Access Levels: TechConnect You can also pull the parameter by changing the connection format within the ...
Posted By GLaDOS Mar 05, 2026 02:11:18 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
HogueGregPLC, I would just add that while I wouldn't say having a short decel time would necessarily damage the motor, I have seen regenerative loads damage motors. On a system utilizing a powerflex 525 to operate a centrifugal pump moving water, the pump would turn off and the water would spin the ...
Posted By GLaDOS Feb 24, 2026 03:08:25 PM
Found In Egroup: Automation Control
\ view thread
Crockett, I haven't experienced this, and I couldn't find a technote specifically for the performance version of the panelview. I did find the following technotes which might help: PanelView Plus appear to freeze or lockup periodically ID: BF1207 | Access Levels: TechConnect PanelView Plus 7 Standard ...
Posted By GLaDOS Feb 17, 2026 04:14:13 PM
Found In Egroup: Advanced Software
\ view thread
Explorer1, Honestly, I have avoided the predefined functions. As you may have noticed with ACM, the documentation is light. The two main documents are: Library Designer and Library Object Manager User Manual Application Code Manager User Manual Unfortunately, you will find very little help from ...
Posted By GLaDOS Feb 03, 2026 02:45:29 PM
Found In Egroup: Advanced Software
\ view thread
Explorer1, That's an interesting idea, I don't think I've ever attempted such an instantiation strategy as I haven't had such a large quantity of repeated parametrized logic before. I grabbed the VSD files too since that's what you are looking at although I suspect any output device from the process ...
Posted By GLaDOS Feb 03, 2026 01:34:00 PM
Found In Egroup: Automation Control
\ view thread
Lovell, Since you are using a panelview 1500 I'm guessing you are limited to firmware v5.1. I'm not sure what functionality is available for that version, but FactoryTalk View ME has such a function built-in: (This is v12, I don't have an older version of ME readily available at the moment). ...
Posted By GLaDOS Feb 01, 2026 09:20:48 PM
Found In Egroup: Advanced Software
\ view thread
Luff, I haven't tried this specific setup. I have seen in the the Factory Talk Security System Configuration Guide it mentions nesting FactoryTalk user groups is not allowed, but I don't see anything specific regarding the Active Directory groups. Although I did see a Rockwell document mentioning nesting ...
Posted By GLaDOS Feb 01, 2026 09:00:50 PM
Found In Egroup: Advanced Software
\ view thread
Explorer1, I can try to take a look at this later in the week if someone else doesn't get back to your first, at the moment I'm a little busy going to some plants to support them. For now, I would like to clarify what you are trying to accomplish. Are you just trying to generate logic external to ...
Posted By GLaDOS Jan 27, 2026 03:29:04 PM
Found In Egroup: Installation & Activation
\ view thread
Galbraith, This discussion post covers the material you need: How to forbid upload the plc grogram from PLC deivce. Document you want is here: FactoryTalk Security System Configuration Guide Otherwise, there is always the option of placing the PLC key-switch in run mode. Prevents all changes and ...
Posted By GLaDOS Jan 22, 2026 08:52:07 AM
Found In Egroup: Automation Control
\ view thread
Rao, I'd recommend taking a look at the Redundant I/O System manual. Particularly, starting on pages 76 and 225. The 50mA fuse looks like a replaceable internal part to the 1715-TADIB16D as seen on page 79, the 5.11kΩ resistor is internal as well, but if you look at the drawing in the manual you will ...
Posted By GLaDOS Jan 09, 2026 01:11:00 PM
Found In Egroup: Automation Control
\ view thread
Shi, The built-in DataLog doesn't have a functionality to trigger the start of Datalogging based upon a specific tag. However, there are ActiveX objects which do have this functionality. Specifically, The MECSVDataLog and the MEDataStorePlus. In the "Connections" tab of the object properties ...
Posted By GLaDOS Jan 09, 2026 12:34:54 PM
Found In Egroup: Automation Control
\ view thread
HANNAFORD, I don't have a direct solution to offer, but I would suggest contacting Rockwell technical support for this one. Sometimes the AOI's do have compatibility issues with older versions of PLC's, and the IO-Link library does list some instructions as having a compatibility issue with the 5370 ...
Posted By GLaDOS Dec 16, 2025 08:48:54 AM
Found In Egroup: Automation Control
\ view thread
Ihor, If have the "Details Pane" option visible for your "Alarm and Even Summary" object, this value is shown for every device alarm in the details pane: ------------------------------ If you answer my questions there will be cake. ------------------------------
Posted By GLaDOS Dec 12, 2025 10:49:58 AM
Found In Egroup: Automation Control
\ view thread
Mir, I'm sure the challenges vary based upon each migration, but in my experience the main difficulty is making sure all the code in the legacy system is understood. SLC systems don't keep comments and descriptors in the PLC, so these are often lost, and it is common to encounter out of date electrical ...
Posted By GLaDOS Dec 11, 2025 08:41:27 AM
Found In Egroup: General Discussions
\ view thread
Central Wisconsin, United States ------------------------------ If you answer my questions there will be cake. ------------------------------
Posted By GLaDOS Dec 10, 2025 03:46:05 PM
Found In Egroup: Advanced Software
\ view thread
Babu, Could you share the actual errors you are getting from the diagnostic list as well? It is difficult to say what to do without knowing exactly how the passed parameters are trying to be used and what the exact error is. I assume you are trying to do some animation based upon the alarm class. ...
Posted By GLaDOS Dec 10, 2025 03:06:04 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Onayli, Thank you for uploading the parameter file. I would continue to suggest that the long decel time may be due to Bus regulation as you are using frequency adjustment for BUS regulation which is normal. I'm not sure there is anything programmatically you can do about that. You may have to install ...
Posted By GLaDOS Dec 08, 2025 09:54:05 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Onayli, Someone had a similar issue recently here: Powerflex 753 PTP mode decel time problem Quite frankly though, I'm not sure if their issue is resolved, but you could look at the technotes in that post and see if anything helps you. One thing to note regarding your t1-t3 and t3-t4 times is that ...
Posted By GLaDOS Dec 08, 2025 09:20:00 AM
Found In Egroup: Automation Control
\ view thread
Bruce, No, the 5370 and the 5380 models do not have a replaceable battery. ------------------------------ If you answer my questions there will be cake. ------------------------------
Posted By GLaDOS Dec 05, 2025 08:57:00 AM
Found In Egroup: Automation Control
\ view thread
Splash, It's interesting that the AOP won't open only on drives 1 & 2. It should be the same AOP as the Datalink is just an option within the AOP, not something from a separate AOP. Have you tried using CCW? I've had powerflex syncing issues with Studio 5000 before, and I got around it by simply changes ...