Posted By Daniel Pryor Mar 22, 2022 07:31:12 AM
Found In Library: Legacy
Posted By Daniel Pryor Mar 22, 2022 07:31:00 AM
Found In Egroup: Legacy
\ view thread
We have Redundant racks with DH Card in Remote IO rack. We did not need to configure routing table. We are communicating between CLX and SLC500. After reading the data we did have to use a FAL instruction to convert the SLC INT format to CLX preferred DINT. Reference screenshot. ------------------------------ ...
Posted By Daniel Pryor Mar 21, 2022 08:22:00 AM
Found In Egroup: Automation Control
\ view thread
You could use RSLinx Classic get the Version, rack size, modules and start a new project. You will have to add the modules manually to the new project. Then do an upload. ------------------------------ Daniel Pryor ------------------------------
Posted By Daniel Pryor Mar 15, 2022 07:45:00 AM
Found In Egroup: Automation Control
\ view thread
You can use a timer or counter to specific message read interval. I can send screenshots of that, if that is what you need. Or do NOT want to use a message instruction at all.?? ------------------------------ Daniel Pryor ------------------------------
Posted By Daniel Pryor Mar 07, 2022 08:08:00 AM
Found In Egroup: Advanced Software
\ view thread
Ray, Including the expression and/or a screenshot would be helpful in assisting you. Kind Regards, Daniel ------------------------------ Daniel Pryor ------------------------------
Posted By Daniel Pryor Mar 07, 2022 08:05:00 AM
Found In Egroup: Automation Control
\ view thread
I has some strange behavior with a panelview, and it was resolved with Factory Default with "Special BOOT Action – Factory Default" Document ID QA27266. ------------------------------ Daniel Pryor ------------------------------
Posted By Daniel Pryor Mar 07, 2022 07:51:00 AM
Found In Egroup: Advanced Software
\ view thread
We had a similar problem back in 2020 when we upgraded to FT V12. If I recall correctly, the solution was what GRO already suggested. ------------------------------ Daniel Pryor ------------------------------
Posted By Daniel Pryor Mar 04, 2022 07:44:00 AM
Found In Egroup: Advanced Software
\ view thread
Private Sub Get_Environment_Variable() Dim sHostName As String Dim sUserName As String ' Get Host Name / Get Computer Name sHostName = VBA.Environ$("computername") Here is a snippet of VBA code we used to display username: ' Get Current User Name sUserName = VBA.Environ$("username") ...
Posted By Daniel Pryor Feb 25, 2022 07:38:00 AM
Found In Egroup: Networks
\ view thread
I would check the Rockwell compatibility guide, also update to the latest firmware. ------------------------------ Daniel Pryor ------------------------------
Posted By Daniel Pryor Feb 24, 2022 08:50:00 AM
Found In Egroup: Advanced Software
\ view thread
I recalled having a similar issue and had to do a delay start on one of the services. I will look into and get back you if I find what service it was. ------------------------------ Daniel Pryor ------------------------------
Posted By Daniel Pryor Feb 17, 2022 08:11:00 AM
Found In Egroup: Advanced Software
\ view thread
Hi Michael, I recall having to assign "FactoryTalk AssetCentre AgentController" service on the Server to Log On to an Asset Center user account. I think it had admin credentials. Daniel ------------------------------ Daniel Pryor ------------------------------
Posted By Daniel Pryor Feb 11, 2022 11:54:00 AM
Found In Egroup: Automation Control
\ view thread
Eileen, I was not able to find the Best Answer??. I went to Chip's reply and found "Reply Privately", and "Mark as Inappropriate" but not Best Answer. See screenshot: ------------------------------ Daniel Pryor ------------------------------
Posted By Daniel Pryor Feb 10, 2022 12:39:00 PM
Found In Egroup: Automation Control
\ view thread
Thanks Chip! That answers my question. :) ------------------------------ Daniel Pryor ------------------------------
Posted By Daniel Pryor Feb 10, 2022 08:06:16 AM
Found In Library: Automation Control
Posted By Daniel Pryor Feb 10, 2022 08:06:00 AM
Found In Egroup: Automation Control
\ view thread
I unfamiliar with this topic, but I am curious where this screenshot came from. We are using FactoryTalk View 12. I looked in the Tag Alarm and Event Server, we have HMI Server. I also looked at ControlLogix device alarms ALARM_ANALOG and ALARM_DIGITAL. No where do I see a check back "Use and evaluate ...
Posted By Daniel Pryor Feb 09, 2022 07:53:00 AM
Found In Egroup: Advanced Software
\ view thread
There is Historian DataLink that can pull data in Excel. We use VantagePoint to create Excel reports. There are other 3rd party tools that can pull and report data from OIS PI database. ------------------------------ Daniel Pryor ------------------------------
Posted By Daniel Pryor Jan 24, 2022 07:38:00 AM
Found In Egroup: Networks
\ view thread
I have used Produced/Consumed tags before, and had no communication problems. I would suggest confirming Power Quality with an Analyzer. Also, you could mirror the L72 port on your Stratix switch and run WireShark to analysis the network traffic packets. ------------------------------ Daniel Pryor ...
Posted By Daniel Pryor Jan 10, 2022 07:54:00 AM
Found In Egroup: Automation Control
\ view thread
This is how we push an Alarm Screen to the front using Global Connections. Reference Attached. ------------------------------ Daniel Pryor ------------------------------
Posted By Daniel Pryor Dec 20, 2021 07:53:00 AM
Found In Egroup: Advanced Software
\ view thread
A feature that gave us a little trouble during FTView12 upgrade from version 9 is the option to "Enable remote diagnostic log collection". ------------------------------ Daniel Pryor ------------------------------