Hello, I would like to ask if we can connect relays ( GE relays ) and transformers to the 1756-EN2T module, as we do with VFDs. if so, can we extend the Module Type dialog box ( see screen shot ). Thanks a bunch
Posted By Ifis May 08, 2024 03:54:43 PM
Found In Egroup: Automation Control
\ view thread
Philip, i appreciate your help and all the details you provided. thank you,
Posted By Ifis May 06, 2024 02:38:00 PM
Found In Egroup: Automation Control
\ view thread
Hello, I Downloaded an AOP on Rockwell website, its version 16 and when i install it, i see no updates in studio 5000 still the same version i had before ( 15.01.01), so i would like to ask 2 quick questions about that : 1/ as shown on the screen shot for the compatibility, Does that mean that i ...
Posted By Ifis May 04, 2024 12:42:00 PM
Found In Egroup: Automation Control
\ view thread
Hello, I came across a project where the studio 5000 program, read the vfd speed and send it to another DCS system. to read the vfd Speed they are using the ''Feedback'' parameter (please see screen shot below) wiche i couldn't confirm in the manual.is that correct? if so, could you please point me ...
Posted By Ifis Apr 17, 2024 05:47:13 PM
Found In Library: Automation Control
Posted By Ifis Apr 17, 2024 05:47:00 PM
Found In Egroup: Automation Control
\ view thread
Hello Batman, Thank you for your response, so I have Revision 9.001 n the Poweflex 6000T and AOP Version 15.01.01.0 (Please see screen shots below ), that means that I need an AOP 9.01 ? Thank you. Best,
Posted By Ifis Apr 15, 2024 11:57:47 AM
Found In Egroup: Automation Control
\ view thread
Hello A N, Thank you for this further explanation, i appreciate your help.
Posted By Ifis Apr 11, 2024 01:07:00 PM
Found In Egroup: Automation Control
\ view thread
Hello, I have a VFD which is not connected in the I/O CONFIGURATION, in a new project i started, showing a yellow triangle ( please see screen shot below). Did i missed details in configuration or, Do i need to install/ Add, additional files ? if yes please provide me with a link where i can get that. ...
Posted By Ifis Apr 11, 2024 11:40:01 AM
Found In Egroup: Automation Control
\ view thread
Thank you Batman, I appreciate your prompt response, I have path 01, and in slot 1 I have the 1756-EN2T Module, it means I'm sending message from CPU to Ethernet Module, and for the class, Attribute definitions will refer to 1756-EN2T manual( Library ), is that correct ? I appreciate your help
Posted By Ifis Apr 11, 2024 10:31:12 AM
Found In Library: Automation Control
Posted By Ifis Apr 11, 2024 10:31:00 AM
Found In Egroup: Automation Control
\ view thread
Hello, i cam across a project where i have a message control routine ( see screen shot below). I didn't understand the Msg configuration, I'm trying to find out the signification of class:56, Attribute : 11 etc, I couldn't find a list of this classes in Rockwell website. I would appreciate any help ...