Posted By gbradley Jan 09, 2023 08:33:00 AM
Found In Egroup: Legacy
\ view thread
Great article, up until the sad part. UPDATE: Rockwell discontinued the MicroLogix 1000 in June of 2017. :' ( ------------------------------ gbradley ------------------------------
Posted By gbradley Sep 16, 2022 08:49:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
So if I have a system with Micrologix 1400 running a couple of Kinetix 300 using Ethernet/IP, external reference, and Indexing, I take it that I am going to have to rewrite the program to work with the 5100 rather than the Kinetix 300. Would I be better off scrapping the Micrologix 1400, and going with ...
Posted By gbradley Sep 13, 2022 09:26:00 AM
Found In Egroup: Legacy
\ view thread
@ Splash The Free version only works with MicroLogix1000, and MicroLogix1100, but I have been able to open and view Ladder Logic files written for Micrologix 1400 with the Free version software. Of course you can't go online or upload or Download with it on a 1400.​ I already have multiple paid ...
Posted By gbradley Sep 13, 2022 09:20:00 AM
Found In Egroup: Legacy
\ view thread
Thanks, It worked on another Laptop. It was probably a Browser Cache thing. Thank-you very much. ------------------------------ gbradley ------------------------------
Posted By gbradley Sep 13, 2022 08:57:00 AM
Found In Egroup: Legacy
\ view thread
Thanks for the clearer instructions. I've tried this, but now I am getting a download error. I have tried in both Chrome as well as Microsoft Edge browsers and I get this same error. ------------------------------ gbradley ------------------------------
Posted By gbradley Sep 13, 2022 08:15:00 AM
Found In Egroup: Legacy
\ view thread
When I go to the Product Compatibility and Download Center and Search for Micrologix 1100 I don't see any of the options that you mention. ------------------------------ gbradley ------------------------------
Posted By gbradley Sep 12, 2022 03:14:00 PM
Found In Egroup: Legacy
\ view thread
EDIT: corrected title adding spaces between words -FL Is the Free version of Micrologix500 starter No Longer available? 9324-RL0050ENE I can't find the Download anywhere. I thought that is a pretty good platform to learn before moving on to Studio 5000, but I can't find the download any longer. ...
Posted By gbradley May 23, 2022 10:30:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
10 days now, and Zero issues. The Broadcast Storm Protection oughta be a selling point on the Stratix 1783-US5T Works great! Thanks
Posted By gbradley May 13, 2022 09:49:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Great idea! I was using an old Stratix switch 1783-US05T with the plastic case which doesn't have the Dip switches. I just swapped it out with a 1783-US5T. So far so good. Wish me Luck. Thanks
Posted By gbradley May 12, 2022 03:45:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Is it only axis 1 that faults or does axis 2 also fault? Both Axis will fault, but not necessarily at the same time. Is your MSG instruction that is supposed to kick the watchdog erroring? MG200:12 for Axis 1, in the sample I am looking at. I don't know, I'll see if I can find out. What is the message ...
Posted By gbradley May 12, 2022 08:15:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Possible, but I have been running my modified program for years and I don't get the error, but as soon as I connect it to the LAN, that's when I get the Watchdog error (E91) Not right away, but pretty consistently within a half an hour or less. It is like I open it up to more traffic, and then it ...
Posted By gbradley May 05, 2022 11:33:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
I have a Micrologix1400 controlling a couple of MPL (MPL-A310F-MJ72AA ) using Ethernet/IP with Kinetix300 drive (2097-V33PR3) MPL-A4560F-MJ72AA and 2097-V33PR6 for The Program is a modification of the Sample program from Rockwell (SMC_ENETIP_ML1400_K300_2AXIS_V1_0 The PLC Program and Drive ...