Posted By Ihor Vasylenko Oct 29, 2025 03:38:08 PM
Found In Egroup: Advanced Software
\ view thread
Very Thanks! -------------------------------------------
Posted By Ihor Vasylenko Oct 29, 2025 01:56:00 PM
Found In Egroup: Advanced Software
\ view thread
Thanks for the answer but my question was what is behavior of second (standby) server in that time when primary is working. Has this (standby) server connection to devices and is there exchange information between standby server and devices in the same time when primary has? ---------------------- ...
Posted By Ihor Vasylenko Oct 28, 2025 10:29:56 AM
Found In Egroup: Advanced Software
\ view thread
Hi! I mean I have two equal KepServer Enterprise wich can work as OPC UA. These servers are on different PC. FactoryTalk Application has OPC UA Connector that can redundant OPC UA Servers. My question is how will work seconds (standby) server when it doesn't have active connection to clients? Has this ...
Posted By Ihor Vasylenko Oct 28, 2025 02:54:00 AM
Found In Egroup: Advanced Software
\ view thread
Hi everyone! There is a question about the working KepServer Enterprise. May be who knows how is working KepServer as OPC UA in the redundancy system in FT Application? For me is interesting has the redundant KepServe connection to the devices and send it the request when client is not connect to him? ...
Posted By Ihor Vasylenko Jul 30, 2024 03:33:00 AM
Found In Egroup: Advanced Software
\ view thread
Hi everybody! May be somebody had the similar problem with FactoryTalk LiveData Pool Gateway service. Sometimes this service took almost all processor time for its needs. And the server with installed KepServer Enterprise, FT View SE Server and FT View Point server begins to slow run. Sometimes ...
Posted By Ihor Vasylenko Jun 11, 2024 05:44:00 AM
Found In Egroup: Automation Control
\ view thread
Hi everyone! I have the dilema in my head. Should I use only this speed-sensor (EK-44395) for directly connection to the module 1444-DYN04-01RA or are there others variants of directly connections of speed to the module 1444-DYN04-01RA by Allen-Bradley sensors? Thanks in advance!
Posted By Ihor Vasylenko Jun 10, 2024 01:56:00 AM
Found In Egroup: Automation Control
\ view thread
Very thanks Philip! that is, this property has nothing to do with data exchange through the producer/consumer. This article (ID: BF29056) is misleading... EDIT: linkified technote for convenience - FL
Posted By Ihor Vasylenko Jun 08, 2024 04:39:00 PM
Found In Egroup: Automation Control
\ view thread
Hi everyone! Could some body explain what does mean the feature in Studio 5000 Logix Designer Professional: Logix Designer Data Exchange? In the Knowelbase there is next information: ID: BF29056. But Produce/Comsume tags are created by Studio 5000 Logix Designer Full Edition... The clear answer ...
Posted By Ihor Vasylenko May 14, 2024 08:19:00 AM
Found In Egroup: Advanced Software
\ view thread
Hello everyone! Mayby somebody met the next problem with HMI servers in FT View Se Distributed system: After Windows update the clients computers cannot to connect to HMI server. After reboot system the server 1 doesn't start properly and standby server cannot connect to server 1. Reboot ...
Posted By Ihor Vasylenko Apr 26, 2024 06:51:00 AM
Found In Egroup: Advanced Software
\ view thread
Thanks!!!
Posted By Ihor Vasylenko Apr 26, 2024 04:47:00 AM
Found In Egroup: Advanced Software
\ view thread
Hi everyone! Is there the possible to work with predefined recipies in ViewDesigner 5000?
Posted By Ihor Vasylenko Apr 11, 2024 10:31:00 AM
Found In Egroup: Automation Control
\ view thread
Very thanks Micro Guy!!!)
Posted By Ihor Vasylenko Apr 11, 2024 10:15:00 AM
Found In Egroup: Automation Control
\ view thread
Thank!!! Also one question)). What I need to type in TargetCfg.Addr if the custom command do not contain some address of register?
Posted By Ihor Vasylenko Apr 11, 2024 09:51:00 AM
Found In Egroup: Automation Control
\ view thread
Thanks Micro Guy for the answer! If I have different number of bytes for request and response, how do I need to configure Local Cfg.Element. Corresponding to the requesting bytes or receiving bytes?
Posted By Ihor Vasylenko Apr 10, 2024 10:46:00 AM
Found In Egroup: Automation Control
\ view thread
Hello everyone! Does have anybody examples of communication Micro800 via Modbus RTU using custom command?