Posted By Ramakrishnan Feb 20, 2026 07:52:52 AM
Found In Egroup: Advanced Software
\ view thread
But, this does not seem to work. Even if I have a user that is only part of a User group with operator access and assigned to one of the areas, they are able to acknowledge alarms in the alarm summary screens for all the other areas. Seems like it uses the Security group permissions rather than the area ...
Posted By Ramakrishnan Feb 19, 2026 06:59:52 PM
Found In Egroup: Advanced Software
\ view thread
Hello @Johann Kotze - Would you know if there is anyway to have users belonging to certain Area groups only be able to acknowledge, suppress, enable/disable alarms based in the "Alarm Group" information? -------------------------------------------
Posted By Ramakrishnan Feb 16, 2026 03:49:00 PM
Found In Egroup: Advanced Software
\ view thread
I came across this KB article. Do you think this will help? BF30642 EDIT: removed the printout of the knowledgebase technote, added the link to access it -FL -------------------------------------------
Posted By Ramakrishnan Feb 16, 2026 11:03:27 AM
Found In Egroup: Advanced Software
\ view thread
Anyway I can get this functionality based on my current version of V15 and FT Batch View V2.01 -------------------------------------------
Posted By Ramakrishnan Feb 12, 2026 04:49:00 PM
Found In Egroup: Advanced Software
\ view thread
Hello, I'm using FT Batch View V2.01 and wanted to know if there is anyway we could restrict operators from having access to the parameters while adding a batch. In the Security Policies for Batch, all I see if a setting for "Add Batch". However, would like to restrict anyone from changing default ...
Posted By Ramakrishnan Feb 12, 2026 04:48:34 PM
Found In Library: Advanced Software
Posted By Ramakrishnan Jan 12, 2026 09:15:26 AM
Found In Egroup: Advanced Software
\ view thread
Hello Will, I seem to be having a similar issue where it takes close to 3 minutes to login whenever I use a windows domain account. Any local FT user logs in immediately (less than 5 seconds). Here is what I'm using in terms of versions and configuration. Hoping you can help out. The knowledge share ...
Posted By Ramakrishnan Jan 08, 2026 02:42:11 PM
Found In Egroup: Advanced Software
\ view thread
Thanks Mike. Appreciate your response. -------------------------------------------
Posted By Ramakrishnan Jan 07, 2026 03:06:04 PM
Found In Egroup: Advanced Software
\ view thread
Hello Chris, Thanks for your response. I already took a look at this spreadsheet. However, noticed the Security Tags used in this spreadsheet are only the following. However, the default list provided within FT View SE has a lot more. Am I correct in assuming that entries not included in the ...
Posted By Ramakrishnan Jan 07, 2026 11:13:00 AM
Found In Egroup: Advanced Software
\ view thread
I would like to ask if there is any tools or scripts that Rockwell has as a default to purge BatchHistoryEx data on a periodic basis. I could not find any database manager in this location (Not in the SQL server that house the databases or on the Batch server) C:\Program Files (x86)\Rockwell Software\Batch ...
Posted By Ramakrishnan Jan 07, 2026 11:09:28 AM
Found In Egroup: Advanced Software
\ view thread
Hello Blake, Sorry for the late response. I was able to resolve this. It was an issue with opening FW ports between the FactoryTalk Directory Server and the RDS servers so any changes in the FT Admin console would take effect across all the FactoryTalk servers -------------------------------- ...
Posted By Ramakrishnan Jan 07, 2026 11:07:00 AM
Found In Egroup: Advanced Software
\ view thread
Hello, Is there any documentation or detailed knowledge base note that explains which graphic object (i.e. button, checkbox etc.) within the PlantPAX 5.10 displays or global objects have these security permissions associated with it. Some of them are pretty self explanatory, but with PLantPAx 5.10 having ...
Posted By Ramakrishnan Nov 11, 2025 04:54:14 PM
Found In Egroup: Advanced Software
\ view thread
So, here is how my Archive Event Filters are selected. Any particular selection you see in this that could results in high number of records. If not, my guess is I'll have to figure out a way to archive and purge records from the BatchHistoryEx database to maintain it. ----------------------- ...
Posted By Ramakrishnan Nov 11, 2025 10:24:09 AM
Found In Egroup: Advanced Software
\ view thread
Hello Reinarts, Thanks for responding. My Batch System is set for "End of Batch" archiving. I took a look at a recent journal files (.evt) and they range between 100,000 to 1,000,000 records. I can attach a few of them for your reference. Would you know if there is a way to reduce the amount of data ...
Posted By Ramakrishnan Nov 07, 2025 11:06:12 AM
Found In Library: Advanced Software
Posted By Ramakrishnan Nov 07, 2025 11:06:00 AM
Found In Egroup: Advanced Software
\ view thread
I currently have a FT Batch V14 installed on a machine and the BatchHistoryEx database is growing at a very high rate (~40GB per month). Looking into the Batch Archiver log (See attachment), I can see there are almost 300000 records being sent to the database at the end of the batch. Could someone help ...
Posted By Ramakrishnan Aug 04, 2025 02:40:00 PM
Found In Egroup: Advanced Software
\ view thread
Hello, I have a SCADA server that hosts FT View SE V13 application. I made a permission change in the Security tab under my Network Directory to "Deny" permissions to certain user group for Alarming. See screenshot below When I tested the functionality of this on a client file run from the SCADA ...