List of Contributions

Lili_acul

Contact Details

Lili_acul


My Content

1 to 17 of 17 total
Posted By Lili_acul Apr 19, 2024 08:47:21 AM
Found In Egroup: Automation Control
\ view thread
Dear Kim, I would suggest downloading and installing AADvance 1715 Trusted Collection Tool from the link below. Collect a full log and the tool will show the physical state of your Trusted system. If your company is enrolled in a Process Safety Support Contract, RA Technical Support can determine ...
Posted By Lili_acul Apr 02, 2024 12:47:00 PM
Found In Egroup: Automation Control
\ view thread
The 5069-IB8S test outputs cannot be set as standard outputs as required by the AT like the 1734-IB8S test outputs (I modified my initial post and pointed to the AID instead). It is important to know what error / fault code is presented in the application, when the 5069-IB8S inputs trip and channel ...
Posted By Lili_acul Apr 02, 2024 09:38:00 AM
Found In Egroup: Automation Control
\ view thread
Thank you for pointing the AT, I was not aware that we allow now Edges without own safety relay (controller). Please see this AID 1125580 for timing adjustments in attempt to eliminate nuisance faults. Best Regards, ------------------------------ Dan Mihalachioaie Sr. Technical Support Consultant ...
Posted By Lili_acul Apr 02, 2024 08:52:24 AM
Found In Egroup: Automation Control
\ view thread
As far as I know Guardmaster Safedge Pressure Sensitive Safety Edge System Bulletin Number 440F requires a dedicated controller, because is looking for a change in resistance when the edge is pressed. It cannot be integrated like a SafetyMat (dry contact between metal plates). Please observe the ...
Posted By Lili_acul Sep 26, 2023 12:46:00 PM
Found In Egroup: Automation Control
\ view thread
Dear Bruce, Thank you for bringing this to our attention. Usually, customers enter documentation feedback using the link present towards the end of any RA manual located in the Literature Library. Unfortunately, link does not work in this Safety Application Technique. I did enter doc feedback to ...
Posted By Lili_acul Jul 10, 2023 10:10:00 AM
Found In Egroup: Automation Control
\ view thread
Dear Konishi, Please download, install and collect a log from the 1715 rack in question, using 1715 collection tool from PCDC: Multi Product Selector (rockwellautomation.com) Please keep in mind the tool can collect only on the local 1715 network and it cannot bridge over Logix backplane (does ...
Posted By Lili_acul Sep 06, 2022 01:42:00 PM
Found In Egroup: Automation Control
\ view thread
Can you please try to collect the log, over Ethernet through the communication card? ------------------------------ Dan Mihalachioaie Sr. Technical Support Consultant Rockwell Automation Listen. Think. Solve. ------------------------------
Posted By Lili_acul Aug 25, 2022 12:51:00 PM
Found In Egroup: Automation Control
\ view thread
Dear Pradeep, Did you try to contact ABB technical support? I would like to know who build and commissioned the SIS. Does your company have an active support agreement in place, and with what company? Please send the information to psafe@ra.rockwell.com (to my attention). Best Regards, ...
Posted By Lili_acul Mar 18, 2022 06:45:00 AM
Found In Egroup: Automation Control
\ view thread
Dear Robert, Firmware version 15.60 is not available on the PCDC (product compatibility and download center) most likely because anomalies fixed in 15.61. Please observe the 15.61 release notes (1756-RN668A-EN-E.pdf). A 1756-L6x series A (1756-BA1 battery) can be rendered unusable is the flash process ...
Posted By Lili_acul Feb 02, 2022 02:36:00 PM
Found In Egroup: Automation Control
\ view thread
Dear Nicola, A support ticket has been created and is actively worked on, based on your RA support agreement. All future information exchange will be documented in the support ticket. ------------------------------ Dan Mihalachioaie Technical Support Consultant Rockwell Automation Listen. ...
Posted By Lili_acul Sep 09, 2021 09:06:00 AM
Found In Egroup: Automation Control
\ view thread
If I understand correctly controller does not transition from Run Mode to Program Mode or it takes a long time to transition. Here is one Knowledgebase ID that explains what might be possible going on. https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/7448 Do you get the message ...
Posted By Lili_acul Aug 03, 2021 07:03:00 AM
Found In Egroup: Networks
\ view thread
Q1: How do I access this value (MOND = Maximum Observed Network Delay time) from within the PLC programming? A1: There is no CIP object for MOND value that can be retrieved with a message or GSV instruction. Q2: Can I reset the Max from in the PLC program? A2: The reset feature is not available ...
Posted By Lili_acul Aug 27, 2015 07:29:00 AM
Found In Egroup: Automation Control
\ view thread
Informatia din cate stiu este impachetata de support tehnic si trimisa la grupul de ingineri care poate decoda evenimentele (hardware or software engineering groups). Daca evaluarea descopera un eveniment raportat precedent raspunsul este destul de rapid. Daca evenimentul este nou, din experienta mea, ...
Posted By Lili_acul Aug 26, 2015 03:06:00 PM
Found In Egroup: Automation Control
\ view thread
See AID 117520: https://rockwellautomation.custhelp.com/app/answers/detail/a_id/117520 ##HL38
Posted By Lili_acul Aug 26, 2015 02:58:00 PM
Found In Egroup: Automation Control
\ view thread
The 1715 I/O modules are not interchangeable with AADvance I/O modules. Keying (pegs) and firmware pieces are different. I would not replace an AADvance SIS with a Logix redundant system. For more information please contact your local RA Solution Architect. ##HL38
Posted By Lili_acul Aug 26, 2015 02:14:00 PM
Found In Egroup: Automation Control
\ view thread
Stefan cand procesorul declara programul invalid, este necesar sa suni RA Support Tehnic, pentru a lansa o investigatie. Foloseste meniul pentru acces direct (Controller section direct dial 100). http://literature.rockwellautomation.com/idc/groups/literature/documents/qr/gmsc-qr003_-en-p.pdf. O ...
Posted By Lili_acul Aug 26, 2015 02:08:00 PM
Found In Egroup: Automation Control
\ view thread
The fault dump utility can not be used on a 1756-L7x processor. All 1756-L7x are equipped with a 1784-SD1 SD card, where information is written. ##HL38