Posted By Hep Apr 19, 2024 12:25:32 AM
Found In Egroup: Automation Control
\ view thread
Hi, Difficult to help you. Maybe is you post the the file, someone can take a look. ------------------------------ Pascal Heitz Technology Consultant - Automation / Digital Twin ------------------------------
Posted By Hep Mar 20, 2024 01:36:49 AM
Found In Egroup: Automation Control
\ view thread
Thanks for finding the solution and for the feedback. ------------------------------ Pascal Heitz Technology Consultant - Automation / Digital Twin ------------------------------
Posted By Hep Mar 20, 2024 01:35:47 AM
Found In Egroup: Automation Control
\ view thread
Conversion is quite easy. In Logix Designer, open controller properties, change controller, chose any 1756-l8 cpu. Maybe the IO configuration will be discarded. ------------------------------ Pascal Heitz Technology Consultant - Automation / Digital Twin ------------------------------
Posted By Hep Mar 19, 2024 01:43:31 AM
Found In Egroup: Automation Control
\ view thread
Hello, FTLogix Echo would be the solution, but you have to do one of this two possibilities: Update to V36, then you can run your 5380 Controller in Echo Or, convert to 5580 in V35 and run into Echo. The third solution would be to have a physical 5380 controller. ------------------------------ ...
Posted By Hep Mar 06, 2024 12:45:00 AM
Found In Egroup: Automation Control
\ view thread
Hello All, Almost everithing as been correctly said, thanks GLaDOS :) Just want to add a small comment. Please, ovoid to have tasks with same priority. Interleaving Tasks is a CPU killer. Better to have tasks that "wait" until another is finished, the whole time will be better than "interleaving". ...
Posted By Hep Feb 16, 2024 06:55:37 AM
Found In Egroup: Automation Control
\ view thread
Hi, I am back. And I can confirm that the Online Configurator is working. ------------------------------ Pascal Heitz Technology Consultant - Automation / Digital Twin ------------------------------
Posted By Hep Feb 16, 2024 12:58:00 AM
Found In Egroup: Automation Control
\ view thread
Hello, A) For standard task, yes, you can copy / paste. But NOT for the safety task. You can export/import or copy / past the program(s) that you have in the safety task. An other option is to use the "Compare and Merge Tool". B) You still must use the MAP Safety tags to be able ...
Posted By Hep Feb 15, 2024 09:32:00 AM
Found In Egroup: Automation Control
\ view thread
Theoretically, after creating a BOM in ProposalWorks, under the "tab" "Documents" we should have the CAD files. If there is not, means, no CAD files are available. I checked several 5380 configuration, none have CAD files ... Let me check internally and I will come later. Here is an example of some ...
Posted By Hep Feb 15, 2024 12:24:01 AM
Found In Egroup: Automation Control
\ view thread
The link is open for everyone, no TechConnect needed. You just need to create an account, the Knlowledge Base is a very useful place to get most of the answers people have regarding RA Products. Less value if you do NOT have a TechConnect contract. Link to Knowledge Base ------------------------------ ...
Posted By Hep Feb 15, 2024 12:20:23 AM
Found In Egroup: Automation Control
\ view thread
Hi, You can also use ProposalWorks locally in your computer (I personally prefer this solution). Download ProposalWorks ------------------------------ Pascal Heitz Technology Consultant - Automation / Digital Twin ------------------------------
Posted By Hep Feb 14, 2024 12:51:55 AM
Found In Egroup: Automation Control
\ view thread
So, try my suggestion and tell if that solve your issue or not ;) ------------------------------ Pascal Heitz Technology Consultant - Automation / Digital Twin ------------------------------
Posted By Hep Feb 13, 2024 01:35:44 AM
Found In Egroup: Automation Control
\ view thread
Hi, Did you often edit (add/remove rung) the PLC online without "re-downloading it" ? That could maybe the cause of slowing down further edits, as the PLC memory becomes fragmented and possibly you could have a Out Of Memory issue. You need to "de-fragment" the PLC memory. Look in this ...
Posted By Hep Feb 09, 2024 01:37:16 AM
Found In Egroup: Automation Control
\ view thread
Hello, You can use FactoryTalk Action Manager. This tool is intend to update the ALL logix Controller clock from a computer. You can directly download it in PCDC Be careful if you have motion in your installation. https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/730060 ...
Posted By Hep Feb 08, 2024 01:06:00 AM
Found In Egroup: Automation Control
\ view thread
Hello, In addition of the great answer you got from the Community, and depending on the controller that you use, you may consider Automatic Diagnostic. https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1132851/loc/en_US Then, with FTView and PanelView5500 you will automatically ...
Posted By Hep Feb 05, 2024 12:32:00 AM
Found In Egroup: Automation Control
\ view thread
Hi, Yes, the new version is called FactoryTalk Action Manager. You can directly download it in PCDC Be careful if you have motion in your installation. https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/730060 EDIT: linkified technote for convenience -FL ---------- ...
Posted By Hep Feb 01, 2024 01:33:36 AM
Found In Egroup: General Discussions
\ view thread
Hi, I see it with Everyone ... ------------------------------ Pascal Heitz[Designation] Technology Consultant - Automation / Digital Twin [Country] ------------------------------
Posted By Hep Jan 19, 2024 01:27:00 AM
Found In Egroup: Advanced Software
\ view thread
Hi Sharan, I guess you speak about FTOptix. This feature will be implemented in v1.4.0, around March. ------------------------------ Pascal Heitz Technology Consultant - Automation / Digital Twin Switzerland ------------------------------
Posted By Hep Jan 15, 2024 01:38:40 AM
Found In Egroup: Automation Control
\ view thread
Hi Guisiano, If you look at the 450L-ENTR User's manual, you will find your answers. GuardShield 450L EtherNet/IP Module CIP Safety Connection User Manual Chapiter 1, Overview. ------------------------------ Pascal Heitz Technology Consultant - Automation / Digital Twin Switzerland ...
Posted By Hep Jan 15, 2024 01:23:00 AM
Found In Egroup: Automation Control
\ view thread
Hi Giacomini, A ggod starting point: RSLogix/Studio 5000: How to transfer the value from the Standard tag to the Safety tag Basically, Safety Program can NOT read standards tag. You have to MAP them as a configuration. Nothing to program. Standard Task have access to safety tag in READ only ...
Posted By Hep Jan 04, 2024 01:18:04 AM
Found In Egroup: Automation Control
\ view thread
Jensen, The best way to understand and learn our Automation Portfolio, is to contact a Rockwell Office near you. Then colleagues will be happy to present our solutions. https://www.rockwellautomation.com/en-us/company/about-us/contact-us.html What Phil is saying, is that if you do not want ...