Posted By Govind Nov 05, 2023 02:50:26 AM
Found In Egroup: Networks
\ view thread
Dear Philip Can you send me the screenshot of 3rd page of this attached excel Sheet. We don't have any Redbox in the architecture. Lan A & Lan B will be connected straight to 18 EN2TP (DAN) modules. IES will be Stratix 5410 Switch 1783-IMS28GRAC. Plant Pax not implemented on the plant as well. Thank ...
Posted By Govind Nov 02, 2023 03:35:00 PM
Found In Egroup: Networks
\ view thread
Dear experts! We have a project for upgrading a complete plant from ControlNet to Ethernet I/P. We tried to use DLR with 3 loops grouping 6-7 PLC in single loop using 5400 switches but later dropped the idea. Now 18 PLCs are communicating to each other through EN2TP modules via LAN A & LAN B switch. ...
Posted By Govind Nov 02, 2023 03:08:00 PM
Found In Egroup: Networks
\ view thread
Any idea when can we expect successor to 1783-ETAP1F ? EDIT: moved to Networks community -FL ------------------------------ Govind ------------------------------
Posted By Govind Jun 10, 2023 05:38:00 AM
Found In Egroup: Automation Control
\ view thread
EDIT: moved to Networks community -FL We have commissioned this project during 2021 but now there is a problem in communication. We have written Cyp messages to detect port failure. So It gives alarms for port drop. E122. E221. E222 Giving Port 1&2 failure. But it is not a complete drop . Communication ...
Posted By Govind May 17, 2023 08:59:00 AM
Found In Egroup: Installation & Activation
\ view thread
rta53.. Yeah. You were right. I Couldn't delete expired activation. Did you succeed? ------------------------------ Govind ------------------------------
Posted By Govind May 16, 2023 07:50:00 AM
Found In Egroup: Installation & Activation
\ view thread
When we checked there was two activation codes. After two hours application shutting down. What can be the issue? ------------------------------ Govind ------------------------------
Posted By Govind May 15, 2023 08:32:11 AM
Found In Egroup: Automation Control
\ view thread
PLC: L73 HMI : PVP7 Performance Disable: Means No control for the second HMI. May be to a default Screen. The thing is I have a common PLC and Both HMI have same application installed. ------------------------------ Govind ------------------------------
Posted By Govind May 15, 2023 07:48:00 AM
Found In Egroup: Automation Control
\ view thread
I have a problem with Redundant HMI operating at same time. PLC is common. Both HMI serving One machine . How can I disable one HMI if the other one is operating. ------------------------------ Govind ------------------------------