Posted By Buck Nov 14, 2025 11:42:46 AM
Found In Egroup: Automation Control
\ view thread
Which version of windows are you using? Studio version 33 and above is not compatible with windows 10. -------------------------------------------
Posted By Buck Mar 25, 2025 09:02:00 AM
Found In Egroup: Automation Control
\ view thread
That's a bummer. We have a lot of customers that have and still want V35 or lower. Other options? Conversion Utility from V36 to V35 In studio allow the search and replace to find and replace instruction mnemonics. ------------------------------ Buck -------------------------- ...
Posted By Buck Mar 23, 2025 10:23:00 PM
Found In Egroup: Automation Control
\ view thread
Are there any plans to include CompactLogix Version 35 in Echo? We have a lot of projects where the customer wants V35 or lower. The alternate would be a conversion utility to convert from V36 to V35. There really is no clean way to do this at this point.
Posted By Buck Oct 04, 2024 10:36:00 AM
Found In Egroup: Automation Control
\ view thread
You have another option to update the PID update rate based on the periodic task. You can use a GSV instruction to get the task rate and write this to the PID .UPD tag. GSV Task T013_PID_Atomizer Rate TaskRate DIV TaskRate 1000000 SH4_XCV302_PID.UPD Where T013_PID_Atomizer ...
Posted By Buck Apr 04, 2024 08:15:00 PM
Found In Egroup: Automation Control
\ view thread
Awesome. Much appreciated. Will give this a shot when I get onsite. Enjoy the day.
Posted By Buck Apr 03, 2024 04:50:00 PM
Found In Egroup: Automation Control
\ view thread
Environment - FTView Studio V14 - PanelView Plus 7 12" Series B F/W V12.1 - Image format .bmp Issue: Each time we compile and download to the series B PV+ the images on the controls expand. Same effect as you would get if you zoomed in on them with paint. Note: this only occurs on the HMI. Runtime ...
Posted By Buck Jun 21, 2023 02:04:00 PM
Found In Egroup: Automation Control
\ view thread
Is there a better active X trend I can use for PVP7 Preformance and View Studio 12? ------------------------------ Buck ------------------------------
Posted By Buck Feb 24, 2023 03:52:00 PM
Found In Egroup: Advanced Software
\ view thread
Enviroment Windows Server 2012 FTEM V2.3 RSLinx V4.3 When trying to browse OPC servers in EnergyMetrix I get the error shown in the attached file. Any help in correcting this would be greatly appreciated. Alternately. Can FT Linx Gateway be used instead of RSLinx as the OPC server for FTEM? ...
Posted By Buck Feb 24, 2023 03:51:35 PM
Found In Library: Advanced Software
Posted By Buck May 25, 2017 12:49:00 PM
Found In Egroup: Automation Control
\ view thread
You might want to check to see if you have the correct gateway address set in your processor. ##HL38
Posted By Buck May 07, 2014 11:46:00 AM
Found In Egroup: Automation Control
\ view thread
Summary: Changing the project directory location I use FT View Studio an a vm. I would like to change the location of the project directory to an external drive. Any ideas on how to do this? ##HL40
Posted By Buck May 30, 2013 02:08:00 PM
Found In Egroup: Advanced Software
\ view thread
Summary: What exactly is file sql_2008_r2-partp.exe for? The file sql_2008_r2-partp.exe is on the FT Metrics install disk. Anyone know what it is exactly? ##HL42
Posted By Buck Mar 04, 2013 09:44:00 AM
Found In Egroup: Automation Control
\ view thread
Thank you for the informsation. Much appreciated. ##HL40
Posted By Buck Feb 07, 2013 03:09:00 PM
Found In Egroup: Automation Control
\ view thread
Summary: Are CAL's required on a domain controller for each OIT device We plan to use a domain controller to administer and maintain user security for multiple PV+ HMI's. Will I need a Win Server CAL for each HMI in my network? Thanks ##HL40
Posted By Buck Jan 17, 2013 09:59:00 AM
Found In Egroup: Advanced Software
\ view thread
Thank you. Answers all I needed ##HL42
Posted By Buck Jan 09, 2013 03:42:00 PM
Found In Egroup: Advanced Software
\ view thread
Summary: Has metrics and vantage point been tested with sql server 2012 and windows server 2012? Anyone know if latest releases of metrics and vantage point are compatable with sql server 2012 (standard edition) and windows server 2012 (standard edition) #HL42 #FTVantagePoint #FTVME #HL42
Posted By Buck Nov 07, 2012 09:53:00 AM
Found In Egroup: Automation Control
\ view thread
Actually, Since you want a cross reference you might want to do the reports from RS5K. Unselect everthing except for the tags in report options. Select print, use the thexps printer option for you printer. This will generate a sorted list of all your tags and includes the location of all instances of ...
Posted By Buck Nov 07, 2012 09:20:00 AM
Found In Egroup: Automation Control
\ view thread
You might want to check the quality of your wiring. Beginning to sound like noise is an issue here. Large enough spikes in your signal conductors will cause the module to fail 1. Are you using shielded cable? 2. Is the shield terminated only at the signal source? In this case the common ...
Posted By Buck Nov 01, 2012 03:31:00 PM
Found In Egroup: Automation Control
\ view thread
The blinking red light indicaztes that either have an open wire or no loop power. Do you have 24VDC loop power? Buck ##HL38
Posted By Buck Jan 13, 2012 09:59:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
I did see that. Was kinda hoping that rockwell already had a formatted list sorta like what used to be in the notes section of the old pront manuals. Go back about 15 years. Yikes. Guess I can't be lazy on this one. ##HL33