Posted By AMIR Mar 22, 2024 10:17:06 AM
Found In Egroup: Legacy
\ view thread
Thanks for the reply. We don't have any problem with upgrading the hardware to Studio5000 that I am familiar with but what I don't know is that how I can convert Logix5 backup file to ACD files in Studio 5000. I also don't have a Logix5 software and when I tried to download it from AB website, it ...
Posted By AMIR Mar 22, 2024 09:50:00 AM
Found In Egroup: Legacy
\ view thread
Hi Folks, In one of our plants, there are a handful of old AB PLCs like PLC2/20, PLC5/20....I was asked to find a solution to upgrade them all to RsLogix5000 but my own search did not find a solid way to handle this conversion. Not sure if there is a way to do this conversion. Could you please advise ...
Posted By AMIR Feb 06, 2024 02:21:42 PM
Found In Egroup: Automation Control
\ view thread
Thanks, looks like it has to be done for every single device in the network. Right?
Posted By AMIR Feb 06, 2024 08:01:00 AM
Found In Egroup: Automation Control
\ view thread
Hi Everyone, I have dozens of devices in my Ethernet network like SMC servos, valve banks, HMI,.... I would like to generate an alarm when there is no communication or cable disconnection between each of them. I can see some of them already offer an alarm bit but not all of them. What would be the ...
Posted By AMIR Jan 18, 2024 01:15:18 PM
Found In Egroup: Automation Control
\ view thread
Got it. Thank you again. ------------------------------ AMIR ------------------------------
Posted By AMIR Jan 18, 2024 10:02:34 AM
Found In Egroup: Automation Control
\ view thread
Hi Philip, I downloaded the EDS from the first link you sent which was in different website than SMC 's website. Do I need to download it from your new link or are they the same. Or may I need to download both ? Thanks. ------------------------------ AMIR ------------------------------
Posted By AMIR Jan 18, 2024 07:46:16 AM
Found In Egroup: Automation Control
\ view thread
Thank you so much. It worked. ------------------------------ AMIR ------------------------------
Posted By AMIR Jan 17, 2024 03:43:00 PM
Found In Egroup: Automation Control
\ view thread
Hi Everyone, I am working on the PLC program with v32 in which they have used SMC controllers, Numatec Ethernet Valve Bank, .... as shown in the attached picture. My questions are: 1- Why I can't see Ethernet module under Control tags to see the input, output data 2- I also cannot see 2 DC digital ...
Posted By AMIR Jan 03, 2024 09:19:00 AM
Found In Egroup: Automation Control
\ view thread
Hi everyone, I am assigned to come up with a design for piston pin overall length measurement using Allen Bradely control equipment. The existing system already has a CompactLogix 5069 PLC and vision system. I am not sure if AB has a specific module or device for length check or not or it suggests ...
Posted By AMIR Oct 09, 2023 02:01:00 PM
Found In Egroup: Automation Control
\ view thread
Hi everyone. I am involved with startup of an old project that they have used a SST-ESR2-CPX-S with two serial ports on it. Communications lights RX,TX on both ports are not flashing but they are connected. I am wondering if that has ever been configured. It has been added to the PLC rack but ...
Posted By AMIR Sep 13, 2023 10:43:54 AM
Found In Egroup: Automation Control
\ view thread
Thank you so much. You made it crystal clear. So appreciate it. ------------------------------ AMIR ------------------------------
Posted By AMIR Sep 12, 2023 02:53:56 PM
Found In Egroup: Automation Control
\ view thread
Thanks for the reply. I actually read that thread but that's not exact problem that I am dealing with. My main issue is the input value that's always there even when my wires are disconnected from the module. This value never gets reset in the program. it comes back when I go online with the controller. ...
Posted By AMIR Sep 12, 2023 01:28:00 PM
Found In Egroup: Automation Control
\ view thread
Hello everyone. I got a situation that I would like to share with you to see who can assist me please. I need to configure an input module 1769-IF4 which was used and designed by others for scaling a flow meter. what I don't get is that the module input already has a value when nothing is connected ...
Posted By AMIR Jun 02, 2023 10:48:00 AM
Found In Egroup: Legacy
\ view thread
Never mind. I got it wrong. ------------------------------ AMIR ------------------------------
Posted By AMIR Jun 02, 2023 10:23:00 AM
Found In Egroup: Legacy
\ view thread
Thanks for the response. It looks like I/0 that are supported by ML1500 are the same as ML1400 . Both are 1769 not 1762 but with different revisions and channel configurations. It is not up to me actually to decide which PLC to convert to. They have everything setup with ML1500 like HMI ,.... but the ...
Posted By AMIR Jun 02, 2023 08:46:00 AM
Found In Egroup: Automation Control
\ view thread
EDIT: moved to Legacy community -FL Hi everyone, I was able to convert an old program with ML1500 processor to a new ML1400 processor, but I noticed that I/O modules are not exactly the same. I have no access to original ML1500 's I/O modules. Was wondering if selecting similar I//O modules that ...
Posted By AMIR May 11, 2023 12:48:53 PM
Found In Egroup: Automation Control
\ view thread
The link is not downloadable. Could you attack ACD file if you have. ------------------------------ AMIR ------------------------------
Posted By AMIR May 11, 2023 11:30:02 AM
Found In Egroup: Automation Control
\ view thread
It can't be downloaded. In what software has it been written? ------------------------------ AMIR ------------------------------
Posted By AMIR Mar 23, 2023 01:00:00 PM
Found In Egroup: Automation Control
\ view thread
Thank you ------------------------------ AMIR ------------------------------
Posted By AMIR Mar 23, 2023 10:04:00 AM
Found In Egroup: Automation Control
\ view thread
EDIT: corrected typo in title -FL Hi everyone, I need to add a new thermocouple to an existing system but there is no spare channel on my existing 1762-IT4 thermocouple modules and can't get them very soon. but I have a spare channel on 1762-IF2OF2 module, but I don't have a chance to ...