List of Contributions

Fran

Contact Details

Fran


My Content

1 to 20 of 25 total
Posted By Fran Mar 02, 2026 07:47:02 AM
Found In Egroup: Automation Control
\ view thread
Tanks @Thomas and @Lili_acul -------------------------------------------
Posted By Fran Feb 26, 2026 10:28:00 AM
Found In Egroup: Automation Control
\ view thread
Euchner has a safety switch for doors. It is a PLe device with 2 OSSD outputs. CES-I-AP-U-C04-USI-115150 (Order no. 115150) | EUCHNER The switch has its own test pulse generator on both outputs. When the door is closed, the outputs signal is off 0.3ms each 100ms. Are there any Rockwell safety input ...
Posted By Fran Jan 31, 2025 08:52:00 AM
Found In Egroup: Automation Control
\ view thread
Sorry, my fault. OLDI was "OnLine Development", this company developed xCopupler an tManager. "Softing" bougth them. I saw OLDI in your post and didn't read slowly. I don't have experience with 1756-CMS1C1 . You can contact with Rockwell support. This forum is not miraculous.
Posted By Fran Jan 30, 2025 02:59:00 AM
Found In Egroup: Automation Control
\ view thread
We are working with these devices from more than 15 years. First, model xcoupler and later model tmanager. We haven't experienced those issues. We have around 10 in our plant. Our unique problem is, once each 2 years more or less, one of them becomes blocked. In order to not stop PLC, we extract ...
Posted By Fran Aug 08, 2024 03:54:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Are there fiber optic between PLC and drive? If yes, please, check if duplex is correct. 5700 randomly start in half duplex. Autonegotiate not good in fiber optic SFP's
Posted By Fran Mar 06, 2024 03:26:00 AM
Found In Egroup: Automation Control
\ view thread
Hello, Check your module. There was a manufacturing fault. Product Notice 2022-05-001 - Allen-Bradley POINT Guard I/O 1734-IB8S/B, 1734-IB8SK/B Intermittent Connection Fault (custhelp.com)
Posted By Fran Dec 18, 2023 04:20:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Yes, but be cautious. I ordered this item in 2-27-2.023, and after several delays, the last scheduled date is 3-1-2.024. This is in Spain. Perhaps in other countries A+B is more serious. ------------------------------ Fran ------------------------------
Posted By Fran Nov 10, 2023 02:32:00 AM
Found In Egroup: Automation Control
\ view thread
In Spain and in september 2023, 1769-AENTR price was 791,62€. And "theoretical" delivery time is around 3 months. ------------------------------ Fran ------------------------------
Posted By Fran Nov 07, 2023 05:49:00 AM
Found In Egroup: Networks
\ view thread
The failure has been going on for around 2 months, at least. Perhaps is a bug or somebody forgot to add the link. ------------------------------ Fran ------------------------------
Posted By Fran Oct 05, 2023 08:04:00 AM
Found In Egroup: Automation Control
\ view thread
First, try to download and install the last version of your studio 5000 version. When i started to use IOLink devices, version 30.0 was only for A+B devices. I think in 30.2 was solved. I use 1734-4IOL. The process is very simmilar to your images. 1- Add EDS master file. (need administrative ...
Posted By Fran Aug 18, 2023 02:14:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Every step i go, there is a new trap from A+B. Today testing feedback in order to know load position. I move several times the drive. I read parameter 5 from UFB card, this paramenter is read only and contains the feedback position. I want to test if this data is read again after drive power restart. ...
Posted By Fran Aug 17, 2023 10:59:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Ryan, Yes i'm at this point. This morning, electricians recheck wiring and found two pairs crossed. After corrections, i tested again, and speed in parameter 134 was stable. But this parameter shows the commanded drive sped X2, for example, if i command drive (in VHz) at 10Hz, parameter 134 ...
Posted By Fran Aug 17, 2023 03:54:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
PF755 20G11NC060JA0NNN, firmware 16.002 20-750-UFB-1, firmware 1.015 I'm testing a lifting application. In this application is very importat to know the position of the load. In order to know load position, we read feedback position of motor encoder. If we use a simple incremental ...
Posted By Fran Jun 06, 2023 02:53:00 AM
Found In Egroup: Automation Control
\ view thread
Perhaps this product can be intersting for you: eATM tManager ControlLogix | Softing You can put this card in a contrologix chasis, read data from cpu's in this chassis or others and store in a database. It supports store and forward. Progamming is not necessary only configuring. Normal configuration ...
Posted By Fran Mar 10, 2023 04:18:00 AM
Found In Egroup: Networks
\ view thread
I have a 24Mb powerpoint about 5200. I share with you ------------------------------ Fran ------------------------------
Posted By Fran Mar 10, 2023 04:17:59 AM
Found In Library: Networks
Posted By Fran Feb 06, 2023 05:20:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
An aproxímate answer is knowledge base ID: QA28660 https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/765056/loc/en_US ------------------------------ Fran ------------------------------
Posted By Fran Feb 01, 2023 07:55:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
We have several cranes controlled by PF755 drives. Is usefull for operator to know hook position aproximately. The motor has incremental encoder, i implemented a datalink to read parameter 847 (Psn Fdbk). When the hook touches maximum up limit switch, the PLC saves this "homing" position. Substracting ...
Posted By Fran Aug 10, 2018 02:42:00 AM
Found In Egroup: Automation Control
\ view thread
One good practice i can see in every cibersecurity manual is to use computers under a non administrative account. I have been testing my Rockwell Software products with an user account in a W7-64 enviroment: -CCW (10 and 11): No issues. Only tested drives functionality. -Factory ...
Posted By Fran Jan 18, 2018 08:24:00 AM
Found In Egroup: Networks
\ view thread
Read this: https://rockwellautomation.custhelp.com/app/answers/detail/a_id/970036/page/1 Is a firmware fault. Load this firmware revision 15.2(6)E0a ##HL100