Posted By Bernard Jan 19, 2023 07:15:00 PM
Found In Egroup: Automation Control
\ view thread
Thanks a lot for the reply. I'm not sure how to assign the 4 bytes to each "container" (INT) or how they arranged / assigned in the UDT. It seems like they have to be in a certain order in the UDT. Strings being at the top. Much appreciated. ------------------------------ Bernard ----- ...
Posted By Bernard Jan 11, 2023 09:18:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
EDIT: linkified for convenience -FL PowerFlex 520-series Adjustable Frequency AC Drive User Manual start @ page 78 this gives you descriptions and definitions of all PF525 par. ​ ------------------------------ Bernard ------------------------------
Posted By Bernard Jan 03, 2023 07:12:00 PM
Found In Egroup: Automation Control
\ view thread
I am trying to experiment with reading parameter values using instance attribute 13 (for example) in the DPI Parameter Object in Ethernet/IP Objects (Appendix C of PF525 Embedded Ethernet/IP Adapter manual. I was successful in getting the parameter name and units, but I'm having a hard time getting ...
Posted By Bernard Jan 03, 2023 07:11:45 PM
Found In Library: Automation Control
Posted By Bernard Dec 13, 2022 05:56:00 PM
Found In Egroup: Automation Control
\ view thread
Thanks a lot for the advice, much appreciated. What I was trying to do was make the following string to display on my FactoryTalk View ME HMI: "Output Current: 5.2A" And use a MSG instruction to obtain the Parameter Name & Units. I succeeded with the ": " and the Parameter Value (Real to String), ...
Posted By Bernard Dec 12, 2022 08:09:00 PM
Found In Egroup: Automation Control
\ view thread
EDIT: moved to Automation Control community -FL I'm having trouble with this concat instruction. I'm can't figure out why Source A will not transfer down to Dest. Source B is just text I entered in. B003.Name is a String_16 MSG instruction used to get the "parameter name" (Output Current) from ...
Posted By Bernard Dec 12, 2022 08:08:35 PM
Found In Library: Automation Control
Posted By Bernard Dec 07, 2022 06:43:00 PM
Found In Egroup: Automation Control
\ view thread
EDIT: moved to Automation Control community -FL When connecting IO references with elements, I can't align both pins on a straight line. It either snaps above or below the element pins. Whenever I insert the IO references or elements onto the FB sheet it snaps to the grid, and when I go to connect ...
Posted By Bernard Dec 07, 2022 06:42:48 PM
Found In Library: Automation Control
Posted By Bernard Oct 29, 2021 03:09:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
I am trying to send (set) start/stop, direction, and speed reference commands to my PF525 VFD. I was able to "get" all sorts of information from the drive using explicit messaging. I was also able to "set" accel & decel times. I have set my VFD start source and speed reference parameters to EtherNet/IP, ...