Posted By Carry Feb 22, 2024 02:07:58 AM
Found In Egroup: Installation & Activation
\ view thread
i check the other PC, that the RSclassic is signal node,and it is working well, and also can't find HOST file in this pc.
Posted By Carry Feb 21, 2024 11:44:57 PM
Found In Egroup: Installation & Activation
\ view thread
Hello Filip, 1)Server state is Running and green 2)in the activation folder don't have HOST file. Can you give me suggestion how to solve it? Can i use the license no. to restore it again, how to restore?
Posted By Carry Feb 20, 2024 03:22:00 AM
Found In Egroup: Installation & Activation
\ view thread
Hello Everyone, Today we find the RSclassic license is missing , and i want to install the license again. before i got the license from AB, but how to install it, can you give me suggestion? Edit: Moved this question to the Installation & Activations forum. -EF
Posted By Carry Nov 28, 2023 12:29:00 AM
Found In Egroup: Automation Control
\ view thread
Hello everyone, i have a system, like below picture. now i set 1783-etap as the ring supervisor mode, after that Link1 light flash green, Link 2 light steady green. is that correct behavior? and some times i find LINK 2 light is off, i check it, and find the ring fault. so reset it use RS5000 then ...
Posted By Carry Aug 25, 2023 03:53:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello Everyone, Now the system have 4 servos ( Kinetix 5500), all of them are running good, but sometimes one of them has the module fault.so this servo will go to stopped status. Can you give me suggestion how to find the reason, how to check it. Thank you ------------------------------ ...
Posted By Carry Jul 26, 2023 04:52:00 AM
Found In Egroup: Automation Control
\ view thread
Hello Fuzzy, Sorry for later reply, now is working, i make a misstake, after i reconnect the cable, need to wait for about 3 minutes, the connection will be automatic reset. ------------------------------ Carry ------------------------------
Posted By Carry Jul 20, 2023 02:43:00 AM
Found In Egroup: Networks
\ view thread
Hello everyone, I have two kinds of network overview, see the pictures , the first one, the plc can't connect the 1783-ETAP, the second one can connect the 1783-ETAP. is it normal? if the plc port one connect to the other device, this device should support 1Gbps ,otherwise can't connect? The first ...
Posted By Carry Jul 18, 2023 12:15:00 AM
Found In Egroup: Installation & Activation
\ view thread
EDIT: moved to Activations community -FL Hello Everyone, i log on Rockwell webisite, and download the IAB software, but the version is 2022, can anyone give me a link that i can download 2023 version? Thank you ------------------------------ Carry ------------------------- ...
Posted By Carry Jul 10, 2023 09:22:00 PM
Found In Egroup: Automation Control
\ view thread
Hello Everyone: so far i have one plc (5580 controller) connect to some IO modules(1734-aentr). if i disconnect the ethernet cable from one of IO module, the IO module will be alarm. then i reconnect the cable, the alarm can't reset automatic. i need to power off the IO module then power on, the network ...
Posted By Carry Jun 29, 2023 03:44:00 AM
Found In Egroup: Automation Control
\ view thread
Hello Everyone, I want to put all the hardware IO link to the arrays. how to easily to implement in the plc code? ------------------------------ Carry ------------------------------
Posted By Carry May 08, 2023 03:28:00 AM
Found In Egroup: Automation Control
\ view thread
Hello Everyone, When running the PVPlus device, there is a cursor on the HMI , do you know how to remove the arrow on the HMI(see the below red marked) ------------------------------ Carry ------------------------------
Posted By Carry Apr 23, 2023 08:04:00 PM
Found In Egroup: Automation Control
\ view thread
Hello Philip, Thank you ,it is working now after i change it ------------------------------ Carry ------------------------------
Posted By Carry Apr 21, 2023 02:53:00 AM
Found In Egroup: Automation Control
\ view thread
Hello Philip, Sorry i don't understand what is your meaning,could you please explain more details, ------------------------------ Carry ------------------------------
Posted By Carry Apr 20, 2023 08:17:00 PM
Found In Egroup: Automation Control
\ view thread
Hello Everyone, I have a plc program with 1768-L45 compact logix , i use RSlogix 5000 20.05 version to open it. How can i use it simulation without real plc? I try to change the control to Emulate 5570, but it will remind a lot of errors,because a lot of IO modules has deleted after i changed the control. ...
Posted By Carry Apr 07, 2023 01:49:00 AM
Found In Egroup: Automation Control
\ view thread
Hello everyone, Now i get a new laptop, and the screen is 4K. When i open the logix 5000 software, the icon is too small(see the picture one ), it is hardly to click. so i change the DPI(see the picture two).after changed, but the top left side, the icon color is purple(see the picture three), so i ...
Posted By Carry Mar 13, 2023 11:58:00 PM
Found In Egroup: Automation Control
\ view thread
Hello Everyone, As we know, when we use the AOI function in ladder program , it will display IN IN-OUT and OUT variable in the program ,see the below picture. But if we use this AOI in ST program , it will not display these variables.It is not good to monitor and testing. i doubt is there any ...
Posted By Carry Mar 09, 2023 12:15:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello Vincent, Thank you for your suggestion . it is solved after i changed the Ethernet topology. This machine has two servo motors.Before the Ethernet topology like that: switch port1 connect to servo1 , then servo 1 connect to servo 2. Now the Ethernet topology like this: Switch port ...
Posted By Carry Mar 08, 2023 01:02:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Sorry. i miss a take, in the device, in the alarm log.,display NODE FLT 01 – LATE CTRL UPDATE ------------------------------ Carry ------------------------------
Posted By Carry Mar 07, 2023 09:54:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello. Everyone. i had a machine on customer side already running well for half a year. but today, the transport stopped once in a while. so the customer check the motion device, there is no alarm message on the device screen, so i online to check the logix 5000, and find the below fault, i check ...
Posted By Carry Feb 27, 2023 01:22:00 AM
Found In Egroup: Automation Control
\ view thread
Hey, in the structured text sub routine, the tag a.b is used for? Are there some manuals that i can download to read. ------------------------------ jin ------------------------------