Posted By Autominion Jul 21, 2022 07:42:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello JOS, I haven't implement it yet because I didn't receive the K6200 yet. In my case, I need to add K6200 to the racks with K6000 (which is obsoleted drive). So I don't have information with your inquiry at the moment. Regards, AM ------------------------------ Autominion ------------ ...
Posted By Autominion Apr 17, 2022 10:41:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Thank you both for the reply and yes I did read the info on both drives bus structure differences, which makes me decide to add K6200 instead to the existing K6000 train of drives that has empty slot on its power rail. ------------------------------ Autominion ------------------------------
Posted By Autominion Apr 08, 2022 12:19:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi, Just want to know if anyone did this before. Can I mount mix Kinetix drives like 6000 and 5700 in same power rail? they'll share the 1756-M16SE Sercos Servo module together. ------------------------------ Autominion ------------------------------
Posted By Autominion Sep 01, 2014 06:40:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Thanks TJ ##HL33
Posted By Autominion Aug 31, 2014 11:46:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Summary: Can I use PF700s to control RDD motor. Hi, I had a project which I plan to use a RDD motor but heard that this only compatible with Kinetix drive. I wanted to use PF700s which we use a lot and I wanted to know if someone here, uses this motor. I need to learn from someone ...
Posted By Autominion Oct 23, 2013 08:23:00 PM
Found In Egroup: Automation Control
\ view thread
Summary: Connection with the controller could not be established. I used RSLinx and that shows the Processor. Hi, Any thoughts how this software tool can't communicate with Logix5572 Processor so I can set the security? Anybody have the version 3.0.0.3 for me to try? Thank you, ...
Posted By Autominion Oct 23, 2013 07:19:00 PM
Found In Egroup: Automation Control
\ view thread
Summary: Prevent copying logic file from RSLogix5000 v.20 Hi, Any thoughts how to protect your PLC code on downloading by 3rd party during equipment testing? Thank you, #HL39 #RSLogix5000 #HL39
Posted By Autominion Oct 08, 2013 06:48:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
thank you very much, and thanks for sharing the manuals. ##HL33
Posted By Autominion Oct 03, 2013 11:27:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Summary: Drive Parameter Hi, Anyone knows what parameter to change in the drive when using a brake resistor? Any safety precaution about wiring will be much appreciated. Thanks you, #HL33 #HL33 #PF755
Posted By Autominion Aug 16, 2013 12:45:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
dmargineau said: The Datalinks feature will have to be setup within both the RSL5K and the PF700S application files (including the 20-COMM-x communications module). For explicit messaging to/from PF 7xy Series VFDs information, refer to the installed communications adapter User Manual. ...
Posted By Autominion Aug 14, 2013 06:36:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
BuckeyeKMH said: You must set up datalinks in the I/O configuration tree or do a Parameter Write message View original I've tried the datalink but it didn't read the exact value from PLC. May I know how does parameter write message works? sample code maybe? Thank you Sir.. ...
Posted By Autominion Aug 06, 2013 12:11:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
follow-up question. what will be the PLC tag to use, when you want to change/manipulate P110 Speed/TorqueMode, using RSLogix5000? thank you.. ##HL33
Posted By Autominion Jul 25, 2013 08:49:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
thanks for the reply sir. It works. ##HL33
Posted By Autominion Jul 25, 2013 08:35:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi, When you used to control a winder using Min Spd/Torque mode P110. Which parameter is your torque reference and your min. speed reference? Can you share how you did it? Thank you, ##HL33
Posted By Autominion Mar 12, 2013 06:46:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Summary: Use DC Bus or 3-phase AC power. Hi, Anyone knows the performance advantage if PF700S drive, feed from DC Bus versus 3-Phase AC power supply? PF700S will be use to control direct motor in torque mode. Thank you, ##HL33
Posted By Autominion Jun 21, 2012 02:55:00 AM
Found In Egroup: Automation Control
\ view thread
Thank you sir for the quick reply.. I'll do that suggested option then. ##HL40
Posted By Autominion Jun 21, 2012 02:04:00 AM
Found In Egroup: Automation Control
\ view thread
Summary: Ver. 5.0 to 6.0 Hi, I build a runtime apps using FTV SE ver.6.0 but the PVP1500 firmware was ver. 5.0. (Not compatible). Had anyone tried to upgrade PVP firmware ver. 5.0 to 6.0 without any issue? Thanks in advance.. #HL40 #HL40 #PVP