Posted By Galbraith Jun 12, 2025 06:49:00 AM
Found In Egroup: Automation Control
\ view thread
Hello Fuzzy Thanks this is a huge help!! ------------------------------ GregGalbraith ggalbraith@seweurodrive.com ------------------------------
Posted By Galbraith Jun 11, 2025 10:59:00 AM
Found In Egroup: Automation Control
\ view thread
Hello All I was searching in the product configurator for cable adapter for 1492-FM20F and 1492-IFM20F-F120-2 terminal adaptor for an upgrade project I am designing. I am updating the PLC hardware from a 1768-L43 with 1769 digital I/O module with a 5069-L306ER and related digital I/O. I would like ...
Posted By Galbraith May 23, 2025 07:57:00 AM
Found In Egroup: Automation Control
\ view thread
Hello Ian, This worked well. I had to do a little math to subtract 1 from the LEN cause the array starts at 0 but the Find starts at 1. I set the FIND to look for Null "$00." Thank you.
Posted By Galbraith May 20, 2025 07:33:00 AM
Found In Egroup: Automation Control
\ view thread
Hello All, I have looked online to see how to do this using the compare "CMP" instruction, but it does not quite work as intended. I am hoping someone here has a work around or if this instruction is renamed in Studio 5K. PLC programming problem. PLC receives a string value from an ...
Posted By Galbraith Nov 22, 2024 08:28:00 AM
Found In Egroup: Automation Control
\ view thread
Hello All, Wow, I had no idea this would spark such a discussion. I do like @Delete idea of creating an AOI with the existing code. I really don't want to mess with it cause well, it just works for the most part. I totally agree with you that the best programmers use the right language for ...
Posted By Galbraith Nov 21, 2024 08:49:00 AM
Found In Egroup: Automation Control
\ view thread
Andrew, I am comfortable with Structured text. The point of converting it is for the off-shift maintenance techs in case they needed to observe the logic it would be friendlier. I am in the process of updating a system. The upgrade includes replacing motors on contactors with VFD's to better ...
Posted By Galbraith Nov 20, 2024 08:12:00 AM
Found In Egroup: Automation Control
\ view thread
Hello Programming Wizards, Is there an easy way to convert a sub-routine written in structured text to ladder logic. I have tried to export/import the sub-routine, and I was not given the option to convert it when I tried to import. I can rewrite but if there is a better and quicker ...
Posted By Galbraith Sep 23, 2024 11:49:00 AM
Found In Egroup: Automation Control
\ view thread
Thanks Ryan. Off to the VM CCW goes. I have ACAD 2024 and it does NOT like anything 32 bit. I had completely uninstalled Office 365 even though it was all 64bit. I had to uninstall Microsoft visual studio redistributes C++ 2012. then uninstall the MS Access engine and install MS Access engine ...
Posted By Galbraith Sep 23, 2024 11:00:00 AM
Found In Egroup: Automation Control
\ view thread
Hello All, I recently got a new laptop Win 11 and installed CCW 22.0. I was able to use CCW and run my project but now I am getting an error message. I ran the "repair" from the installation thinking that maybe something got corrupted. After the repair installation I am still getting the same message. ...
Posted By Galbraith Sep 23, 2024 09:50:00 AM
Found In Egroup: Automation Control
\ view thread
Hello All, Is there a way to use exponents in a timer instruction? I have process where I have long intervals between actions. I have a skimmer that must run 5 mins out of every 2 hours. and I would much rather enter it as an exponent. Thanks for the input. ------------------------------ ...
Posted By Galbraith Sep 03, 2024 03:20:00 PM
Found In Egroup: Installation & Activation
\ view thread
Hello, I got another error as well this time with the EDS services.
Posted By Galbraith Sep 03, 2024 03:16:00 PM
Found In Egroup: Installation & Activation
\ view thread
Hello, Thanks for the quick reply. I don't think I have anything the plant that is V19. I do know of a few machines are on V18 and V16. I had issues with those installs as well. My co-worker has Win10 and had no issues with installing the older software. I am currently installing V21 and ...
Posted By Galbraith Sep 03, 2024 02:43:00 PM
Found In Egroup: Installation & Activation
\ view thread
Hello, I am getting this error message repeatedly. I have a new laptop with Win11 and I am trying to install my Rockwell software. I am not sure what to do. Any ideas would be greatly appreciated. ------------------------------ Greg Galbraith ------------------------------
Posted By Galbraith Jul 29, 2024 08:26:00 AM
Found In Egroup: Automation Control
\ view thread
Thank you!! exactly what I was looking for. ------------------------------ Greg Galbraith ------------------------------
Posted By Galbraith Jul 29, 2024 07:55:00 AM
Found In Egroup: Automation Control
\ view thread
Hello, I am looking for the manual that explains the calculation for the 2085-IF8 for the different input settings. for example 0-20ma, 4-20ma, etc. I know the range is INT that value ranges from -32768 to 32767. I am trying to set up my analog value so I can back calculate the physical measurement ...
Posted By Galbraith Jul 24, 2024 01:24:00 PM
Found In Egroup: Automation Control
\ view thread
Hello Ryan, OK I tried the E/IP setting as you recommended, and the HMI did not take to it. I switched my HMI and PLC communication settings to Modbus Master and it connected right up. It also helps to insure I had the right IP address in the PLC. Fat fingers do it every time. ...
Posted By Galbraith Jul 23, 2024 03:56:00 PM
Found In Egroup: Automation Control
\ view thread
Hello Ryan, I am actually using a SEW DOP (Beheir? that is who actually makes it. SEW just brand labels it.) That would be great if I could use ETHERNET/IP. This was not ever an option before. I was under the impression that only PV800 could use the Ethernet/IP? I am currently using FW20. ...
Posted By Galbraith Jul 23, 2024 02:14:00 PM
Found In Egroup: Automation Control
\ view thread
Hello, I am having a bit of an issue with my PLC communicating with my HMI. The HMI I am using has a verity of AB communication protocols I can choose from. 1) MicroLogix Ethernet 2) SLC/PLC5 Ethernet 3) Ethernet/IP I can also choose from good ol' Modbus Master or Modbus Slave ...
Posted By Galbraith Jun 24, 2024 10:36:00 AM
Found In Egroup: Automation Control
\ view thread
Hello all, Could one of you guru's point me to the tech note or manual that explains how to set up the PLC time to sync with our server clock. I went online with the controller and clicked on the properties tab of the controller --> time -> advanced and it the text box it showed an IP address ...
Posted By Galbraith May 14, 2024 03:08:00 PM
Found In Egroup: Automation Control
\ view thread
Hello Philip, They get this message when they try to open Studio. I fixed it on mine once before. I had to go into Factory Talk Admin Console and add my username and password as an Admin. We use a VM and I require all my users to rename their VM so I can see who it is on the license server.