Posted By Emre Karakaya Sep 27, 2024 08:54:34 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
We checked PTP Command. After we enter PTP Setpoint, So it saves the position to PTP Command. After that we put a timer. It counts 100ms and after trigger "Move" bit.
Posted By Emre Karakaya Sep 27, 2024 01:08:22 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
There are many different devices in the system. For example, we are using Powerflex 525 drivers in this project, but we are not doing PTP control here. Such a situation did not occur in any of them. We perform PTP control with Powerflex 755 drivers. We did not experience any problems with the other parameters ...
Posted By Emre Karakaya Sep 27, 2024 12:59:19 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
We checked and changed RPI but it didn't change the result. Sometimes, this situation happens again.
Posted By Emre Karakaya Sep 27, 2024 12:53:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
I contacted Rockwell technical support but I did not receive any feedback regarding the solution to the problem. Actually, machine manufacturer asked to us that problem. This is their first time using Rockwell. They don't have much experience with Rockwell products. So we try to find a solution for ...
Posted By Emre Karakaya Sep 26, 2024 12:06:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
There are 3 machines like that. PLC version 35, drive version 14 on machine 1. PLC version 36, drive version 16 on machine 2 and 3. We are experiencing this problem on all machines.
Posted By Emre Karakaya Sep 26, 2024 12:00:38 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
We checked PLC program a lot of time but there is no zero speed anywhere. Also we didn't have any communication problem among devices.
Posted By Emre Karakaya Sep 25, 2024 08:53:15 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Thank you Vincent, We didn't see any drive error, when we encountered this problem. Only motor doesn't move. When I checked Parameter 770, I can see Move bit is triggered. We didn't add any new equipment recently.
Posted By Emre Karakaya Sep 25, 2024 07:19:03 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
We use 4 pieces Powerflex 755 AC Drive with 20-750-ENC-1 encoder card. We use 5V TTL encoder with them. 2 axes are vertical so we used Torque Prove here, also there are motors with brake, 2 axes are horizontal. We use PTP Control here. The application is briquette production machine. When motor reaches ...
Posted By Emre Karakaya Sep 25, 2024 06:44:51 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello Batman, Motor doesn't move but this doesn't happen everytime. For example, machine works two weeks or a month without any problem, but after a while, the machine remains motionless and waits. After that, we cancel "Run" command and trigger again and send "Move" command, the machine starts ...
Posted By Emre Karakaya Sep 20, 2024 09:02:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello, We do PTP control application with Powerflex 755 AC Drive. We use "Run" command firstly and it stays constantly. We send different positions with "Move" command but sometimes "Move" command doesn't work stable. For example it works 1000 times but it doesn't work after that. To fix this problem, ...
Posted By Emre Karakaya Aug 23, 2024 08:57:00 AM
Found In Egroup: Automation Control
\ view thread
Hello, I have a Solartron 7835 Densitometer module and I need to read frequency value with 1756-HSC module. I did necessary setting on Studio 5000. The operational mode is Frequency mode. Rollever, preset and scale values are 0. You can see cable wiring at belove. Densitometer has 2 signal outputs ...
Posted By Emre Karakaya Jul 24, 2024 01:25:12 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Thank you for your answer. We try to solve it with standard controller but I think there is no way to solve it without using safety plc.
Posted By Emre Karakaya Jul 23, 2024 02:51:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi, I use 1756-L71 CPU with Powerflex 527 AC Drive. When I arrange axis settings, I get a fault like SafeTorqueOffActiveInhibit fault. Safe Torque Off jumper wired. The drive display shows Inhibit S05 SAFE Torque OFF. We read Safe Torque Off Mode as "1". Also we read Safety Supervisor State as "5". We ...
Posted By Emre Karakaya Jul 27, 2023 03:51:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello Jeff, Thank you for your answer. I don't use Ethernet communication on this project. I only take a signal output of PLC for some periods and enter DI2 of Powerflex 755's IO Card. When PLC sends signal, I do 1 step incremental position and it continues when signal comes. When I upload project, ...
Posted By Emre Karakaya Jul 26, 2023 06:05:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello Everyone, I have a strange problem on Powerflex 755. We use 15kW 30 A drive and do incremental position control. When we download parameters to the drive, the motor works fine but after we cut off the power and start the drive, the motor vibrates and runs loudly. After we upload backup ...