Posted By Patrick Dixon Mar 20, 2024 01:19:58 PM
Found In Egroup: Advanced Software
\ view thread
I got a new external drive, installed a Win 10 VM on it, install FT View v11 on it, and now intend to do the development on that system. I will then export what I edit to XML, import to my other VM which has FT View v13, and will then be able to test it on my licensed system with Emulate. Thanks for ...
Posted By Patrick Dixon Mar 15, 2024 09:28:07 AM
Found In Egroup: Advanced Software
\ view thread
Thanks for the reply. Since I have a development kit license on one of my VMs, if I have another VM with prior versions those won't be licensed. I assume when you point the VM at the host for licensing, you need to do something in FT Activation Manager so that the license is available? ----------- ...
Posted By Patrick Dixon Mar 15, 2024 07:45:00 AM
Found In Egroup: Advanced Software
\ view thread
I have a customer with FT View SE v11. My development system has v13. I imported their backup (APB file) into my system, which upgraded their v11 application to v13. How do I make edits and install them on their v11 system? Can I have both a v11 and v13 FT View studio on my development system ? -- ...
Posted By Patrick Dixon Mar 13, 2024 10:01:56 PM
Found In Egroup: Advanced Software
\ view thread
Thank you for the responses. I need to make it clear what I am trying to do. I get the customer's archive (APB file) I import that archive into my development system I want to create a copy of the customer's application that will be the working copy. That will allow me to make edits to the working ...
Posted By Patrick Dixon Mar 13, 2024 05:01:00 AM
Found In Egroup: Advanced Software
\ view thread
Now the issue is trying to remove the HMI server from the app and import. I see no way to do this. I tried importing without restoring the HMI server, and it doesn't work. What do I need to do to import? ------------------------------ Patrick Dixon[Designation] PE, PMP www.DPAS-INC.com ----- ...
Posted By Patrick Dixon Mar 12, 2024 08:27:44 AM
Found In Egroup: Advanced Software
\ view thread
I got my answer in FactoryTalk View Site Edition User's Guide "NOTE: You cannot attach to an existing HMI server that is being used in another application." So now my question is can I have multiple HMI servers in the same server machine with the same license? The objective is to make a duplicate ...
Posted By Patrick Dixon Mar 11, 2024 11:53:02 PM
Found In Library: Advanced Software
Posted By Patrick Dixon Mar 11, 2024 11:53:00 PM
Found In Egroup: Advanced Software
\ view thread
Is it possible to have an HMI server with multiple FT SE applications? It looks like the server can only have one project (application). I tried importing an archive into the same HMI server as another application and it said I would have to remove the HMI server from the application to import. I don't ...
Posted By Patrick Dixon Jan 24, 2024 08:46:53 AM
Found In Egroup: Automation Control
\ view thread
Following up to see if there has been any progress on applying feed forward? ------------------------------ Patrick Dixon PE, PMP www.DPAS-INC.com ------------------------------
Posted By Patrick Dixon Nov 08, 2023 07:41:17 PM
Found In Egroup: Automation Control
\ view thread
I am interested to know how it is performing now, after following the recommended steps. ------------------------------ Patrick Dixon PE, PMP www.DPAS-INC.com ------------------------------
Posted By Patrick Dixon Nov 06, 2023 07:32:42 PM
Found In Egroup: Automation Control
\ view thread
The first step is to ensure the loop is stable without feedforward. In the configuration I designed this is done by setting CL_FF_Gain=0. Then perform some closed loop setpoint changes and observe the stability of the loop. If the loop responds in a stable way to a setpoint change or disturbance (water ...
Posted By Patrick Dixon Nov 02, 2023 11:46:14 AM
Found In Egroup: Automation Control
\ view thread
"because it is added to the PID algorithm output rather than multiplied." It is multiplied in the example I show with CL_FF_Gain "Maybe better explained with aid of diagrams?" I think I already provided those diagrams "if Piotr's dosing pump were replaced with a flow meter and flow control valve, ...
Posted By Patrick Dixon Oct 29, 2023 11:44:00 AM
Found In Egroup: Automation Control
\ view thread
Ratio can work well when your PV is a flow that you want to maintain in proportion to another flow. If CL_Feedback was chlorine flow and SPCascade was water flow, the RatioProg or RatioOper parameter can be used to specify the ratio of chlorine flow to water flow. In order to do this, you need the f ...
Posted By Patrick Dixon Oct 29, 2023 11:43:29 AM
Found In Library: Automation Control
Posted By Patrick Dixon Oct 26, 2023 08:48:59 PM
Found In Egroup: Automation Control
\ view thread
When you ask "how to set" assume you are asking how to configure it. You appear to have a case where you have the concentration of chlorine (CL_Feedback) being controlled by regulating flow of chlorine from a variable speed pump (CL_VFD_Pump_Speed). That should work with appropriate PID tuning. However, ...
Posted By Patrick Dixon Oct 11, 2023 03:11:51 PM
Found In Egroup: Automation Control
\ view thread
We looked at the configuration of every 1734, they all match 100 mbps full duplex, same as the ethernet adapter in the processor rack. Therefore, it doesn't look like there are any mismatches. Looking a lot more like it is installation/cabling/hardware. ------------------------------ Patrick Dixon ...
Posted By Patrick Dixon Oct 10, 2023 03:24:00 PM
Found In Egroup: Automation Control
\ view thread
Got got into 2 of the 1734 that seem to be working and confirm DHCP is enabled with 999 switches, but they are rev C. Documentation 1734-UM018F-EN-E - May 2023 page 35 says "The 1734-AENT/C adapter should be configured using only DHCP." Attached are photos of one of the devices. We think there is another ...
Posted By Patrick Dixon Oct 10, 2023 10:27:01 AM
Found In Egroup: Automation Control
\ view thread
We found all thumbwheels on the 1734 are set to 999. That means an invalid value makes it use DHCP for its network address. We don't have a plant network operating yet, so I assume the DHCP server would be the 1756-EN2TR? ------------------------------ Patrick Dixon PE, PMP www.DPAS-INC.com ------ ...