Posted By Patrick Dixon Jan 10, 2026 02:46:12 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
The link to the Windows compatibility article does not work: ------------------------------ Patrick Dixon[Designation] PE, PMP www.DPAS-INC.com ------------------------------
Posted By Patrick Dixon Jan 10, 2026 02:43:26 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
How is the tolerance set for the movement? I assume there is a setting in the Ultra Master software for the servo drive to adjust it? ------------------------------ Patrick Dixon[Designation] PE, PMP www.DPAS-INC.com ------------------------------
Posted By Patrick Dixon Jan 08, 2026 03:21:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
My customer has a Ultra 200 series digital servo drive DDM 075 connected to 1746-HSTP1 module in a SLC 500. Every scan we send the same command distance through the HSTP1 as the target position, and we get back the actual and encoder feedback. We assume the drive uses the encoder feedback to control ...
Posted By Patrick Dixon Jan 08, 2026 03:07:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
I have a customer with an Allen Bradley DDM-075 servo drive. We want to look at the configuration/diagnostics in the drive, and we think we need Ultra Master software and Windows XP. How do we get the software? Is there any documentation on how to connect to the drive and use the software? ...
Posted By Patrick Dixon Jan 04, 2026 03:34:38 PM
Found In Egroup: Automation Control
\ view thread
I am trying to implement the recommended unlatch of S:MINOR shown on page 25 of Publication 1756-PM014O-EN-P - September 2024. To be clear: My code is function block It is implemented in an add on instruction It does not see S:MINOR, so I don't know where that comes from My code is running in ...
Posted By Patrick Dixon Jan 04, 2026 03:02:39 PM
Found In Egroup: Advanced Software
\ view thread
Thanks for the reply, I don't have that service ------------------------------ Patrick Dixon[Designation] PE, PMP www.DPAS-INC.com ------------------------------
Posted By Patrick Dixon Jan 04, 2026 08:54:34 AM
Found In Egroup: Advanced Software
\ view thread
I am not sure which service FTAE.Web.DataProvide.Historian.exe is. Here are the running processes I have that are pertinent to Rockwell. Is it one of these? ------------------------------ Patrick Dixon[Designation] PE, PMP www.DPAS-INC.com ------------------------------
Posted By Patrick Dixon Jan 04, 2026 08:40:43 AM
Found In Egroup: Automation Control
\ view thread
Thank for you the responses. I am glad to hear that the minor faults do not impact CPU performance. I generally don't like any faults to persist, so I am inclined to set Lag = 1 when it is less than 1 and use a SEL block to use the raw signal instead of the LDLG signal in that case, which adds some additional ...
Posted By Patrick Dixon Jan 01, 2026 07:10:00 PM
Found In Egroup: Automation Control
\ view thread
I made an interesting discovery. I was getting minor faults with "(Code 04) Arithmetic overflow. Result of an arithmetic instruction out of range". I traced it to a LDLG block where the Lag value was 0.0. Documentation says 0 disabled the Lag, but internally it actually requires the value to be >= 1. ...
Posted By Patrick Dixon Jan 01, 2026 07:09:33 PM
Found In Library: Automation Control
Posted By Patrick Dixon Dec 31, 2025 02:10:00 PM
Found In Egroup: Advanced Software
\ view thread
I have a stand alone Win10 machine running Emulate v33, Logix 5000 v32, and FTVIew SE local. When I open my FT View SE application, I notice "SQLServer Windows NT - 64 bit" (which is sqlservr.exe) using 18% of the CPU. That seems high. My understanding is this is SQL Compact / embedded databases, no ...
Posted By Patrick Dixon Dec 30, 2025 06:58:27 PM
Found In Egroup: Automation Control
\ view thread
Got the answer, looks like it fixed the problem Technote QA26747: Why am I getting a popup box that states "Another user is making a change to the controller."? ------------------------------ Patrick Dixon[Designation] PE, PMP www.DPAS-INC.com ------------------------------
Posted By Patrick Dixon Dec 29, 2025 07:22:04 PM
Found In Library: Automation Control
Posted By Patrick Dixon Dec 29, 2025 07:22:00 PM
Found In Egroup: Automation Control
\ view thread
I have Logix Emulate v33.00.00, Logix Designer v32.03.00 and I have some PlantPAX 4.0 objects in my code. I am running on Win10 Pro 64 bit. It is on my laptop, so there are no other users and it is impossible for any other user to be accessing anything on my machine. However, every time I try to download/upload/go ...
Posted By Patrick Dixon Nov 25, 2025 03:53:24 PM
Found In Library: Legacy
Posted By Patrick Dixon Nov 25, 2025 03:53:00 PM
Found In Egroup: Automation Control
\ view thread
My customer has a SLC 505, but does not have a commented config file for the current code. They have the original config file with comments and address descriptors. The code was never downloaded, so the MAC address is default. The uploaded code obviously has no comments or descriptors. They want to edit ...
Posted By Patrick Dixon Nov 20, 2025 09:40:57 PM
Found In Egroup: Automation Control
\ view thread
Yudaman! I accepted the contact, please send. ------------------------------ Patrick Dixon[Designation] PE, PMP www.DPAS-INC.com ------------------------------
Posted By Patrick Dixon Nov 20, 2025 09:16:00 PM
Found In Egroup: Automation Control
\ view thread
I uploaded a PanelView Plus 600 and saved the MER file, but when I try to add it to the FactoryTalk ME Application Manager it says it is protected. I assume it is password protected? Is there any way to get around this, since nobody at the customer facility knows this password and the prior integrator ...
Posted By Patrick Dixon Nov 20, 2025 08:58:00 PM
Found In Egroup: Automation Control
\ view thread
The facility has 2 identical machines. Machine 2 works perfectly, Machine 3 does not. The customer suspects there is something different in the PLC. The logic was uploaded from both machines and a comparison showed there are logical differences. Both machines have SLC 505 with ethernet communications ...
Posted By Patrick Dixon Jun 12, 2025 10:10:00 PM
Found In Egroup: Advanced Software
\ view thread
I upgrade from PlantPAX 4.0.02 to 4.10.06, that fixed it. The dot release has the fix, the old release has the problem. The ticket can be closed ------------------------------ Patrick Dixon[Designation] PE, PMP www.DPAS-INC.com ------------------------------