Posted By Petr Miksovsky Sep 25, 2025 01:38:45 AM
Found In Egroup: Automation Control
\ view thread
Solution 3 Downgrade Compare Tool from v11 to v10. -------------------------------------------
Posted By Petr Miksovsky Mar 25, 2025 02:50:00 AM
Found In Egroup: Advanced Software
\ view thread
What's New Current Release: FactoryTalk LogixAI Release Notes V3.02.00 - November 2024 FactoryTalk® Analytics™ LogixAI® embeds analysis and machine learning technology into the Logix control environment. Our patented modeling algorithm advances automation systems to the next level. The predictive ...
Posted By Petr Miksovsky Jan 28, 2025 03:21:22 AM
Found In Library: General Discussion
Posted By Petr Miksovsky Jan 28, 2025 03:21:00 AM
Found In Egroup: General Discussions
\ view thread
It is a known fact that Rockwell sometimes does not recognize its catalog numbers. However, in your case it is a bug in the "configurator". It is the same algorithm as in ProposalWorks and there is a bug there too. As an interesting example, I am adding an another example of how the Rockwell portal ...
Posted By Petr Miksovsky Jan 28, 2025 03:04:48 AM
Found In Library: General Discussion
Posted By Petr Miksovsky Jan 09, 2025 05:45:00 AM
Found In Egroup: Advanced Software
\ view thread
I keep reading about how AI will change everything and create application programs instead of human programmers. A good and complete catalog software with a precise description of the catalog numbers would be enough for me. How can I believe in AI when I can't find the item 9702M-OPXUPL2XLRT131 in the ...
Posted By Petr Miksovsky Jan 09, 2025 05:44:28 AM
Found In Library: Advanced Software
Posted By Petr Miksovsky Jan 09, 2025 01:47:00 AM
Found In Egroup: Advanced Software
\ view thread
FactoryTalk Optix Runtime - Feature Upgrade L to XL Perpetual ID: 9702M-OPXUPL2XLRT131 DS: S3/84H
Posted By Petr Miksovsky Aug 16, 2024 04:11:00 AM
Found In Egroup: Automation Control
\ view thread
I am sorry for my note but are you sure that AMIR has "TechConnect" access to KnowledgeBase ? Wouldn't be better to show the page in user manual ? The manual has free access. https://literature.rockwellautomation.com/idc/groups/literature/documents/um/viewme-um004_-en-e.pdf page 103/471
Posted By Petr Miksovsky Jul 17, 2024 04:27:00 AM
Found In Egroup: Automation Control
\ view thread
Just quick note why somebody doesn't use FBD too. You can not use indirect addressing in RSLogix/Studio 5000 Function Block programming language. This is not supported.Interesting thing is that CCW supports indirect addressing in FBD.
Posted By Petr Miksovsky Jul 17, 2024 03:04:00 AM
Found In Egroup: Automation Control
\ view thread
English is not my native language, so maybe I understood wrong, but the topic is "Event Input Interrupt". So the word input I understood like local input
Posted By Petr Miksovsky Jul 17, 2024 01:04:00 AM
Found In Egroup: Automation Control
\ view thread
According to me, event from local input is impossible with this CompactLogix.
Posted By Petr Miksovsky Jul 12, 2024 02:24:00 AM
Found In Egroup: Legacy
\ view thread
Just a quick note SLC : Memory Module Compatibility Table https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/15983/loc/en_US#__highlight
Posted By Petr Miksovsky May 17, 2024 02:07:00 AM
Found In Egroup: Automation Control
\ view thread
I'm sorry and maybe I missed something, but could you explain to me how you want to test the program for the LOGIX5575 processor using the Logix Echo software?
Posted By Petr Miksovsky May 16, 2024 08:27:00 AM
Found In Egroup: Installation & Activation
\ view thread
Yes I know this link but it is a patch solution or should I say temporary solution. There is no overview catalog software with a clear interpretation of catalog numbers. In addition, in the link to the knowledge base, they only write about FactoryTalk View, so in this case it is only very partially applicable, ...
Posted By Petr Miksovsky May 16, 2024 07:22:00 AM
Found In Egroup: Installation & Activation
\ view thread
It would be possible to see some publicly available document that supports your words ? Because if I try to look up part number 9324-RLDT3ENT. I get this response "The search for "9324-RLDT3ENT" returned no results."
Posted By Petr Miksovsky May 16, 2024 02:52:00 AM
Found In Egroup: Installation & Activation
\ view thread
Does anyone know why are there a different catalog numbers on the activation certificate than on the order ? Does anyone know where is the documentation for the catalog numbers from the activation certificate ? Petr
Posted By Petr Miksovsky May 06, 2024 03:07:00 AM
Found In Egroup: Advanced Software
\ view thread
The question is, should the HMI be very colorful or dull gray? I don't know myself. I am interested in this manual. https://literature.rockwellautomation.com/idc/groups/literature/documents/wp/proces-wp023_-en-p.pdf page 18/56 "8.1 Color Conventions"
Posted By Petr Miksovsky Apr 23, 2024 01:22:00 AM
Found In Egroup: Automation Control
\ view thread
Just a quick comment I installed version 36 and since then I have Fatal Error 0xe0434352 The KnowledgeBase reads ID: BF30201 | Access Levels: Everyone. If possible, use Virtual Machines to isolate Studio 5000 Logix Designer V20-V31. Simple Conclusion Rockwell Software does not like ...