Posted By AutomateSHANE Jan 19, 2026 09:37:43 AM
Found In Egroup: General Discussions
\ view thread
I assume so. Try it in Firefox or Edge to check. I mainly use Vivaldi and Firefox. Ditched Chrome years ago. -------------------------------------------
Posted By AutomateSHANE Jan 19, 2026 09:31:11 AM
Found In Egroup: Advanced Software
\ view thread
My thoughts as well. No limit on OPC UA strings. So it would just be a single-dimension string array of size 10. Logix strings are 82 Bytes with one being reserved for the size, so 81 characters max, IIRC. -------------------------------------------
Posted By AutomateSHANE Jan 19, 2026 09:23:01 AM
Found In Egroup: Advanced Software
\ view thread
Ok, then what do the calls look like? Is it successive, i.e. one call for each station, back to back? Or is there some time in between? You could try setting station to null at the end of the method and maybe sleeping the thread between calls. I'd probably start stepping through with the debugger ...
Posted By AutomateSHANE Jan 19, 2026 08:45:29 AM
Found In Egroup: Advanced Software
\ view thread
It looks like the variable station isn't declared locally. Any reason why? Are you using it outside of this method? Can you try it with a station variable declared local to the method? -------------------------------------------
Posted By AutomateSHANE Jan 19, 2026 08:22:05 AM
Found In Egroup: Advanced Software
\ view thread
Is there a way to use Optix logger for the connected postgre? No, because the PostgreSQL database is still not recognized as a store type in Optix and the Optix logger can only connect to one of the store types which are currently supported by Optix. The example given was merely a widget which uses ...
Posted By AutomateSHANE Jan 19, 2026 08:00:49 AM
Found In Egroup: Advanced Software
\ view thread
Ah, so it does stay in RetainedAlarms even after acknowledgement? I was under the impression it didn't. If so, yeah that would be the best way. -------------------------------------------
Posted By AutomateSHANE Jan 19, 2026 07:41:02 AM
Found In Egroup: Advanced Software
\ view thread
In these situations, its always better if you share with us more details up front. Your code is based on the example, but if it isn't exactly the same then it will be helpful for us to see your specific code. You can see in the example there are functions for browsing the controller and clearing existing ...
Posted By AutomateSHANE Jan 19, 2026 07:02:00 AM
Found In Egroup: Advanced Software
\ view thread
I posted it specifically because it does address your need in C#. Now that you've actually bothered to read the whole conversation it seems you just don't understand it. Since you've replied there, I'll explain more there. -------------------------------------------
Posted By AutomateSHANE Jan 19, 2026 07:01:00 AM
Found In Egroup: Advanced Software
\ view thread
The escape characters for carriage return and new line (\r\n) are not recognized anywhere in Optix Studio. You cannot directly put them in a string formatter nor directly in a text box. When working in Optix Studio, there are two ways to get a new line of text: Use the keyboard shortcut of holding ...
Posted By AutomateSHANE Jan 17, 2026 12:55:00 PM
Found In Egroup: Advanced Software
\ view thread
It has been addressed before in this community. Always make sure to search here for an answer in an existing conversation. ftoptix-escape-character-in-string-formatter -------------------------------------------
Posted By AutomateSHANE Jan 16, 2026 05:03:48 PM
Found In Egroup: Automation Control
\ view thread
Ok, good news! I've learned from the libraries manager that they now also include the AOIs in PCDC if you only want those instead of building it out in ACM. You can download the Machine Builder Libraries in PCDC and find the AOIs corresponding to OEE. ------------------------------------------ ...
Posted By AutomateSHANE Jan 16, 2026 04:53:01 PM
Found In Egroup: Advanced Software
\ view thread
Hi, I took a look into this and the short answer is yes, there is a way to do this. I'll step through my observations and thoughts. AlarmsWithEmailNotification This is just a collection of custom alarm types, each derived from one of the base alarm types, which have been extended to include a NetLogic ...
Posted By AutomateSHANE Jan 16, 2026 03:29:41 PM
Found In Egroup: Advanced Software
\ view thread
Thanks for making this post. I remember now with more clarity. The ability to add a comment to an alarm instance is baked into the alarm type, but performed via NetLogic associated with the alarm widgets. It sounds like once a comment is added during a session, the alarm instances retains it going forward. ...
Posted By AutomateSHANE Jan 16, 2026 12:22:17 PM
Found In Egroup: Automation Control
\ view thread
Unfortunately, I do not have it in my digital scrapyard. Stand by, though, I'll see if someone else can get it for you by next week. -------------------------------------------
Posted By AutomateSHANE Jan 16, 2026 09:43:00 AM
Found In Egroup: Automation Control
\ view thread
I don't have the tools available to test at the moment, but I've got some thoughts. As Suryawanshi pointed out, the .ACC value is going to be overwritten by the instruction internally each scan as long as it is enabled. I understand what you're trying to do by putting the accumulated value close to the ...
Posted By AutomateSHANE Jan 16, 2026 09:29:28 AM
Found In Egroup: Advanced Software
\ view thread
Soumen, Right-click the Kind property and use Reset to clear it. Then, set the Node class property to 'Any'. That should allow to point to any node generically, without matching type. -------------------------------------------
Posted By AutomateSHANE Jan 16, 2026 09:21:38 AM
Found In Egroup: Advanced Software
\ view thread
I'm pretty sure that with 'Approve remote access' checked it requires the operator at the panel to approve your request to initiative VPN access. That also requires that the Optix application on the panel has everything configured to do this: System object and FactoryTalkRemoteAccessWidget. You can ...
Posted By AutomateSHANE Jan 16, 2026 09:13:16 AM
Found In Egroup: Advanced Software
\ view thread
I'm quite confident it has to do with the number of event instances. With a small burst (I don't know, say 5 to 50 events) it may not be a problem. But with hundreds of events at once I'm really not surprised that eventually you encounter a problem. At baseline, the panel may have enough resource overhead ...
Posted By AutomateSHANE Jan 15, 2026 04:34:00 AM
Found In Egroup: Advanced Software
\ view thread
Help Files Style Sheets Configure a Style Sheet From the Optix Resources thread at the top of this community: GitHub Change Style Sheet Example Seismic FT Optix Technical Training There is documentation, you just are not bothering to use it. --------------------------------- ...
Posted By AutomateSHANE Jan 14, 2026 08:44:32 AM
Found In Egroup: Advanced Software
\ view thread
To me, that just means the runtime service crashed or was actually killed by the OS. Could be due to a resource error or memory fault. A full crash dump from the device would paint a clearer picture for Tech Support to analyze. One thing you can do is to start getting an idea of if the OptixPanel is ...