Posted By Adam Ackerman Mar 04, 2026 04:24:00 PM
Found In Egroup: Installation & Activation
\ view thread
Digital purchases will come with an email that contains the certificate that has the serial number and product key on it, this certificate also has the Version. If you have an old physical copy, then the certificate is inside the case and has all of the same information. I am confident that a physical ...
Posted By Adam Ackerman Mar 03, 2026 11:17:29 AM
Found In Egroup: Advanced Software
\ view thread
I have mentioned this on other similar post and while it's not the intended use, it works pretty well. IF you are converting to Logix based alarms, you can assign different severities (or other defining values) to the alarms. Then in Optix you can place alarm banners that only display values with ...
Posted By Adam Ackerman Mar 03, 2026 08:17:02 AM
Found In Egroup: Advanced Software
\ view thread
I have been working on the assumption that this will either be a natural "function" of the SCADA features once they are implemented or that the SCADA Features will make this need obsolete because a different interaction process will be introduced. Either way, after much deliberation, I have not been ...
Posted By Adam Ackerman Mar 02, 2026 02:21:45 PM
Found In Egroup: Installation & Activation
\ view thread
nope -------------------------------------------
Posted By Adam Ackerman Feb 20, 2026 09:34:26 AM
Found In Egroup: Advanced Software
\ view thread
That is exactly one of the behaviors I was curious about, the claim that no licenses exist. That is a result of trying to use activation Manager for the Vflex, even if Activation Manager is local to the same server that ThinManager is on there is something about the startup timing that can result in ...
Posted By Adam Ackerman Feb 20, 2026 08:05:35 AM
Found In Egroup: Advanced Software
\ view thread
There is also a Service Pack for V14.1, I have not installed it yet and I have no idea what is addressed in it; could be helpful. Where do your VFlex Licenses reside? I have never had luck with running those through Activation Manager and now just advise my customer to use Master Licenses directly ...
Posted By Adam Ackerman Feb 19, 2026 01:10:59 PM
Found In Egroup: Advanced Software
\ view thread
Mine recreated and connected on its own. Mine failed after a version upgrade form V14 to V14.1. My backup did not have a password set; it prompts for a password but per documentation you can leave it blank. I have never tried to change the user for the server or services, now that I think about mine ...
Posted By Adam Ackerman Feb 19, 2026 10:34:28 AM
Found In Egroup: Advanced Software
\ view thread
just had to figure this out ThinManager: Database Password prompt after upgrade -------------------------------------------
Posted By Adam Ackerman Feb 18, 2026 07:40:15 AM
Found In Egroup: Advanced Software
\ view thread
If you are using Logix based alarms, I have done a similar thing through that. You can separate "alarms" out by severity (there are other properties you can use, but my use case went with severity) and then you just configure a new banner or summary to filter for only that severity. Not entirely the ...
Posted By Adam Ackerman Jan 26, 2026 03:05:45 PM
Found In Egroup: Installation & Activation
\ view thread
I don't know what the right answer is, but as a Global OEM I can tell you what we do with RA software. RA has a transfer to ownership process; you can buy the software as your company and then transfer that software to the customer. The process is dumb and unless you are going to do this constantly, ...
Posted By Adam Ackerman Jan 26, 2026 11:27:45 AM
Found In Egroup: Advanced Software
\ view thread
"Nevertheless, I know many folks still are not considering UX when they design their HMI and they just want it to look the same as it has for the last 30 years." Fighting this now; I keep saying that the ME projects we do can all be replaced with Optix, the response I get is "well they will look ...
Posted By Adam Ackerman Jan 26, 2026 07:32:00 AM
Found In Egroup: Advanced Software
\ view thread
If you are only interacting with a PLC tag through this button, you want to use a object that has the "Activate" or "Active" ( I can never remember what the property name is). A mouse event is not a maintained event, meaning if you have to press and hold the button for something like a manual move of ...
Posted By Adam Ackerman Jan 23, 2026 08:32:00 AM
Found In Egroup: Advanced Software
\ view thread
I would not say that this is the result of the migration, your application backup is likely good. The View studio version is not supported on the OS and the Version is very much out of RA support. V5 came out in 2005 or 2006 and was the first version to carry the "FactoryTallk View Studio" naming, ...
Posted By Adam Ackerman Jan 23, 2026 07:50:40 AM
Found In Egroup: Advanced Software
\ view thread
You need to update your entire environment, V5.1 is ONLY supported on Windows XP, nothing current will run on Windows 7. Time to spend some money and get your system up to Windows 11 (or even just Windows 10) and move to View Studio V16. You will need to do some converting; you cannot go straight ...
Posted By Adam Ackerman Jan 06, 2026 07:52:30 AM
Found In Egroup: Advanced Software
\ view thread
Great collection Blake, thank you for putting this together. Being January, I see we missed the V1.7 release in December, do you have any insight on upcoming release dates? I am most interested in V1.8 and potential that Optix SCADA will be included in that release. ----------------------------- ...
Posted By Adam Ackerman Dec 30, 2025 11:34:00 AM
Found In Egroup: Advanced Software
\ view thread
ah, yeah, I was missing the correct workflow. -------------------------------------------
Posted By Adam Ackerman Dec 30, 2025 09:39:00 AM
Found In Egroup: Advanced Software
\ view thread
I may be missing something with the new Tag Browser behavior. I have a Global Object that references a program-scoped structure, for example: (::[PLC]Program:My_Program.Axis_07.Some_Tag) Within the Global Object, .Some_Tag is already defined at the object level (e.g. (#4.Some_Tag)), where #4 is intended ...
Posted By Adam Ackerman Dec 18, 2025 12:57:41 PM
Found In Egroup: Advanced Software
\ view thread
Fantastic response! thank you, Phil! -------------------------------------------
Posted By Adam Ackerman Dec 18, 2025 07:51:50 AM
Found In Egroup: Advanced Software
\ view thread
So, on the view studio side we originally sold them the following: 9701-VWSS000CW10LPE – View SE Server (1 seat) 9701-VWSCWPE – View SE Client (2 seats) They were about to renew with the following: 9701M-VWSSPT10 – View SE Server + 10 Client Bundle 9701M-VWSDRT10 ×2 – View SE Client ...
Posted By Adam Ackerman Dec 17, 2025 03:17:00 PM
Found In Egroup: Advanced Software
\ view thread
I am going to setup a lab to work through the Network Distributed concept, but I would appreciate some input. I have a ThinManager pre-production/test environment that was built out as a single VM with ThinManager, View Studio, and the Clients all local to the single VM. We are now ready to move ...