Posted By Rodrigues Jan 14, 2026 12:08:44 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Well, we just discovered the mode selection bits on the 1794-ID2. We also noticed that the old software was configured for a quadrature encoder (X4), with the count enable bit and rollover enabled...thank you for your help! -------------------------------------------
Posted By Rodrigues Jan 11, 2026 06:45:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi, While the 1794-AENTR was added as Rack-Optimized, the only option to add 1794-ID2 is specialty connection. Is this correct? -------------------------------------------
Posted By Rodrigues Jan 08, 2026 02:07:00 PM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi, We have a revamp situation with the following setup: Originally, the application used a FlexLogix 5434 controller with a 1794-ID2 module reading an incremental encoder 847T-DN2C-RG00500. We are now migrating this system to a CompactLogix 5069-L306ERM, while keeping the 1794-ID2 module via a 1794-AENTR ...