Posted By Filip Freitag Mar 27, 2024 11:37:21 AM
Found In Egroup: Installation & Activation
\ view thread
Yea, Flex licenses are specific, but very universal. They work for versions they are entitled to thou, so best way to go around is to check the documents on compatibility, eg. CodeMeter and Flexera activations compatibility and differences (IN9769, rated E for Everyone). Oh, CodeMeter stick! As long ...
Posted By Filip Freitag Mar 27, 2024 10:34:01 AM
Found In Egroup: Installation & Activation
\ view thread
For Flexera Dongles - as long as you keep the license files copy (separate USB stick for example) and you install the HASP drivers from Thales you should be good even on Win 11 machines with the licensing. Use what you're more comfortable with, but for the newer stuff I'd recommend FT Linx. But RSLinx ...
Posted By Filip Freitag Mar 21, 2024 08:59:33 AM
Found In Egroup: Installation & Activation
\ view thread
Yup yup - "Exception thrown by the target of an invocation" means in most situations a WMI corruption. Running the scripts in the document is one of the ways to fix it. ------------------------------ Best Regards Filip Freitag Technical Support Associate Engineer Connected Services email: RASWSup ...
Posted By Filip Freitag Mar 18, 2024 08:48:59 AM
Found In Egroup: Installation & Activation
\ view thread
There might be a situation where the information from the rehost didn't register correctly - you can contact the Activations Team to straighten it out. ------------------------------ Best Regards Filip Freitag Technical Support Associate Engineer Connected Services email: RASWSupport@ra.rockwell.com ...
Posted By Filip Freitag Mar 15, 2024 09:45:55 AM
Found In Egroup: Advanced Software
\ view thread
Only in case of the CodeMeter/Current licenses, the activation manager needs to configure the CodeMeter service to be a server - IN9199 - FactoryTalk Activation Manager: Sharing CodeMeter licenses You can do it by going to Advanced -> Configure CodeMeter and checking the Run Network Server, followed ...
Posted By Filip Freitag Mar 14, 2024 06:52:49 AM
Found In Egroup: Installation & Activation
\ view thread
You should be able to run the FTAC and FT Actvation Server on the same machine, as FTAC will install the version of FT Activation Manager it requires. After that, you can update the FT Activation Manager to a higher revision, as it is backwards compatible with the software. Also, what do you mean as ...
Posted By Filip Freitag Mar 11, 2024 08:22:00 AM
Found In Egroup: Installation & Activation
\ view thread
Correct installation failed code is 1935, resulting in installation failure 1603. Component based on the picture is FT Diagnostics 6.30, which is a part of FactoryTalk Services Platform (FTSP). Please try to download and install FTSP 6.30 first and then install the CCW. ------------------------------ ...
Posted By Filip Freitag Mar 01, 2024 01:00:00 PM
Found In Egroup: Installation & Activation
\ view thread
Apologies, but in this case the only way around is to call the Activations Support team. Follow this link to contact the activations team on the line - Phone/Onsite Support ------------------------------ Best Regards Filip Freitag Technical Support Associate Engineer Connected Services email: ...
Posted By Filip Freitag Feb 28, 2024 09:06:51 AM
Found In Egroup: Installation & Activation
\ view thread
Yes, they are kinda hidden in those optional downloads, and not all versions of the Studio 5000 have them. RSLogix 5000 as they are a legacy software do not have multi-version packages (except some media releases and v20.05/06). ------------------------------ Best Regards Filip Freitag Technical ...
Posted By Filip Freitag Feb 28, 2024 09:00:00 AM
Found In Egroup: Installation & Activation
\ view thread
Download and install needed versions :) A tip from me - use multi-version packages. Most popular versions of Studio 5000 are included in there, and it's a smaller install package. Eg. Extended Multi-Version: On that installer thou - watch out for the v33-35 - if you check it as is, you will install ...
Posted By Filip Freitag Feb 22, 2024 08:53:00 AM
Found In Egroup: Installation & Activation
\ view thread
There might be a possibility that the license is a CodeMeter type. In Start Menu look for Codemeter->CodeMeter Control Center: In the window check if the Rockwell Automation Inc. License is Gray/Green/Red: If Red - Write down the 130-* and contact the RA Activation support team for license recovery ...
Posted By Filip Freitag Feb 21, 2024 04:48:19 PM
Found In Egroup: Installation & Activation
\ view thread
First way to start is to go to the Advanced and to Refresh This Server - check if Server state is Running and green. Next thing is to check if you see any license starting with HOST* in the Activation folder (location highlighted): If the files are there, there might be an issue with reading them. ...
Posted By Filip Freitag Feb 20, 2024 04:11:00 PM
Found In Egroup: Installation & Activation
\ view thread
------------------------------ Best Regards Filip Freitag Technical Support Associate Engineer Connected Services email: RASWSupport@ra.rockwell.com web: http://support.rockwellautomation.com ------------------------------
Posted By Filip Freitag Feb 20, 2024 03:54:00 PM
Found In Egroup: Installation & Activation
\ view thread
Or you can try to download and install a newer version of the DeviceNet Tag Generator. Since we need a newer one you can try to install v25. Here is a link to download it, might worth a shot - QA9750 - RSLogix 5000 DeviceNet Tag Generator (rated E for Everyone :P) ------------------------------ Best ...
Posted By Filip Freitag Feb 19, 2024 09:04:56 AM
Found In Egroup: Installation & Activation
\ view thread
The Authorization number is a 10-digit number that begins with 0 - example 0000012345. Check if you can pass with his example, or contact the activations team to confirm on the license numbers. Order ID might begin with one 0 number - check if the situation is the same. ------------------------------ ...
Posted By Filip Freitag Feb 12, 2024 09:40:20 AM
Found In Egroup: Installation & Activation
\ view thread
To use v20.01 or 20.03 you need to have a Legacy License - any new licenses for Studio 5000 are for versions 20.05 and newer - won't activate those legacy versions. ------------------------------ Best Regards Filip Freitag Technical Support Associate Engineer Connected Services email: RASWSupport@ra.rockwell.com ...
Posted By Filip Freitag Feb 12, 2024 06:48:43 AM
Found In Egroup: Installation & Activation
\ view thread
Hello Maybelle! Hmm, that's interesting - what do you mean by 20.03 not being compatible with your devices? 20.03 should be backwards compatible with previous v20 revisions, just like 20.04/5/6. When it comes to downgrading - go for it, just uninstall v20 you have installed and install the downgraded ...
Posted By Filip Freitag Feb 08, 2024 08:58:04 AM
Found In Egroup: Installation & Activation
\ view thread
Hello Sir, The licenses that you're showing are a Temporary License for Studio 5000 v36 and a Legacy Lite versions. By the way the bindings show up you have a CodeMeter dongle stick, which accepts Current license activation. For Studio 5000 the activation has to be version Current or 27 and higher ...
Posted By Filip Freitag Feb 07, 2024 11:49:21 AM
Found In Egroup: Installation & Activation
\ view thread
Yes, you're right. For most of hardware the latest firmware releases are late against the view for the AOPs. Although similarly can be said on the AOPs as well, so right now the only thing we can do on 15.2(8)E5 case is... wait. ------------------------------ Best Regards Filip Freitag Technical Support ...
Posted By Filip Freitag Feb 06, 2024 12:12:19 PM
Found In Egroup: Installation & Activation
\ view thread
In most situations the firmware of that revision is located in the main firmware release (no E*, just E). ------------------------------ Best Regards Filip Freitag Technical Support Associate Engineer Connected Services email: RASWSupport@ra.rockwell.com web: http://support.rockwellautomation.com ...