Posted By Vincent Bourrelly Dec 01, 2025 03:43:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello Gaam your configuration with Gi1/1 set to Switch For Automation is correct. In the Manual 2094-UM002 you have to search for The power cycle capability ( I guess it is chapter 4) For the Stratix powercycle it was just a reminder 😉 Regarding the extended fault code. please revied ...
Posted By Vincent Bourrelly Nov 28, 2025 02:56:11 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi Gaam Thanks , So I think that your Startix Configuration is correct , could you just detail what is the equipment connected on Gi1/1 ? If you refer to the user Manual 2094-UM002, you will found that we mentioned that there is power cycle limits... The power cycle capability cannot exceed 2 ...
Posted By Vincent Bourrelly Nov 27, 2025 06:18:03 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi Gaam sorry I was on customer visit those days. So indeed restarting often a drive is definitely not recommended, that could create indeed situation with communication failure and even more problematic issues like stress on the electronic and power components, limiting time life expectation of the ...
Posted By Vincent Bourrelly Nov 20, 2025 06:07:04 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi Rohit, When you says that it stays on "2" it's on the seven segment display that you see "2" What are the drives status indicators and what is the status in logix application online ? If the drive stuck in sercos phase 2 it's often a wrong address, Fiber problem, FW compatibility, or logix ...
Posted By Vincent Bourrelly Nov 20, 2025 02:47:24 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello Valverde. Your actual motor MPL-B540K-MJ72 is equipped with an absolute encoder ((M) Multi-turn High-resolution Encoder (absolute feedback)) if you change for an S it stays absolute but single turn . For the absolute position retention , you need at least one homing procedure using the MAH ...
Posted By Vincent Bourrelly Nov 13, 2025 02:36:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
You are welcome Farid, Can't you just simply remove the associated motor (and/or drive) from the application if not used anymore ? Regards ------------------------------ Vincent BOURRELLY Senior Technology Architect Mechatronics (Motion Control & Safety) Please don't forget to LIKE and highlight ...
Posted By Vincent Bourrelly Nov 10, 2025 07:35:01 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello Farid All what Batman said is very correct , A more direct option is to go online and just inhibit the axis, directly go to the drive properties , look at the connection tab and check the box Inhibit Module. very simple. regards Vincent ------------------------------ Vincent BOURRELLY ...
Posted By Vincent Bourrelly Nov 10, 2025 07:22:17 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello Gaam You are welcome, we try too help , it's the goal of the community :) If you have controller, Motion, automation devices please select the "Multiport Automation Device" I have check the CUP , and it seams ok so nothing to change at this level. The latest FW for the Stratix 8000 ...
Posted By Vincent Bourrelly Nov 07, 2025 03:22:51 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi GAAM, Thanks for sharing your table, indeed I have already seen it. it gives a clear view of the Kinetix implementation. Are there any additional elements connected to the Stratix? About the multi-port configuration: Please avoid making changes while the machine is running. Since multiple Kinetix ...
Posted By Vincent Bourrelly Nov 06, 2025 03:19:00 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello GAAM So I see an issue on your configuration of the smartport . They are assigned to "Switch For Automation". This is not correct if you connect to those port Automation devices (even if you have Etaps in the line) . You must change the configuration to "Automation Device" or "multiport Automation ...
Posted By Vincent Bourrelly Nov 05, 2025 03:17:40 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi Gaam It seams that you can access with the web page to the startix 8000 so it is a sign that the express Setup have been executed. In the Stratix 8000 you can configure Smart port could you check the Smart port configuration. To make sure that they are correct for the Motion devices connected ...
Posted By Vincent Bourrelly Nov 04, 2025 03:22:01 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello Ballou As usual manuals are a good start , and I strongly recommend you to have a good look at them . What manuals do you have ? Kinetix 350 Single-axis EtherNet/IP Servo Drives User Manual is a good start. In the Chapter #2, #3 and #4 you will found details about wiring . It is not a complex ...
Posted By Vincent Bourrelly Oct 15, 2025 02:14:40 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Indeed a lot of currant oscillation/instability . What is the mechanical system attached to the Motor ? what type of operation he is doing ? ------------------------------ Vincent BOURRELLY Senior Technology Architect Mechatronics (Motion Control & Safety) Please don't forget to LIKE and highlight ...
Posted By Vincent Bourrelly Oct 14, 2025 11:26:01 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello Rivera You will found all details in the following manual https://literature.rockwellautomation.com/idc/groups/literature/documents/rm/motion-rm003_-en-p.pdf regards Vincent ------------------------------ Vincent BOURRELLY Senior Technology Architect Mechatronics (Motion Control & Safety) ...
Posted By Vincent Bourrelly Oct 14, 2025 03:17:41 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi Rivera, Thanks for the feedback So maybe that was already like that before ! If further investigation is required, then trends becomes essential Best regards ------------------------------ Vincent BOURRELLY Senior Technology Architect Mechatronics (Motion Control & Safety) Please don't ...
Posted By Vincent Bourrelly Oct 13, 2025 03:17:48 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
hello adnan Usually IGBT over heat could be caused by sustained overloads, overvoltage or overcurrent... or even short circuits If you have motor over heating and fdbk failure (maybe due to motor heat)... indeed like said Batman you should look at motor and cable. in addition Cable length ...
Posted By Vincent Bourrelly Oct 13, 2025 02:33:31 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hi Riviera What Batman told you about the motor replacement is correct. But did you mount the motor correctly ? I mean alignment, preload...etc It is important to trends with velocity, current and position error to better understand what is going on. Are you sure that the system was not already ...
Posted By Vincent Bourrelly Oct 08, 2025 08:24:20 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Thanks for the feedback. The change of encoder is the faster and easier solution. Let us know if you need more details regards ------------------------------ Vincent BOURRELLY Senior Technology Architect Mechatronics (Motion Control & Safety) Please don't forget to LIKE and highlight ...
Posted By Vincent Bourrelly Oct 02, 2025 04:36:47 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
If I can, I would like just to add a comment on this solution. It is recommended to add an interlock in front of the SSV/GSV to avoid collision of others message, that could be sent at same time to drives. For that you can use in front of the GSV or SSV the AxisName.ConfigUpdateInProcess . Then, if ...
Posted By Vincent Bourrelly Oct 02, 2025 03:44:23 AM
Found In Egroup: Drives, Motion Control & Low Voltage Products
\ view thread
Hello GAAM Thanks for the clear feedback Having the managed switch not configured can generate problems. Because it will behave like a standard switch . If you do the Express Setup, that will at least configure the PTP and QoS , those are important for CIP Motion protocol, because that guaranty ...